P.O. Box 1306, Newport Beach, California 92663 • Phone: 714-751-0488 • Fax: 714-957-1621 • E-Mail: techservice@newmarpower.com
www.newmarpower.com
1
M-PT-U-LNGFM
As of July 2008
Phase Three
Three Stage Smart Charger
Installation/Operation Manual
Models: PT 80, PT24-45U, PT-24-95U
Section Topic
Page
QUICK REFERENCE DRAWING 2
I) GENERAL INFORMATION 3
II) IMPORTANT SAFETY INFORMATION 3
III) INSTALLATION 4
A) Materials Provided 4
B) Location. 4
C) Mounting 4
D) D.C. Output Wiring 5
E) Multiple Unit Parallel Wiring 6
F) A.C. Input Wiring 6
IV) OPERATION 8
A) Three Stage Charge Regimen 8
B) Time-Out Circuit 8
C) Gel-Cell/Lead-Acid Selector Switch 9
D) Remote Monitor Panel Option 9
E) Temperature Compensation Option 9
F) Equalize Timer Option 10
G) Cooling Fan 11
H) Power On Indicator 11
I) Output Ammeter 11
V) APPLICATION NOTES 11
A) Start-Up 11
B) Constant Versus Occasional Use 11
C) Proper Load Sizing 11
D) Operation with Engine 11
E) Operation as a D.C. Power Supply
or Radar Rectifier 11
VI) SPECIFICATIONS 12
VII) TROUBLESHOOTING 12
VIII) BATTERY CARE TIPS 13
IX) REFERENCE APPENDIX 14
X) PT 80/PT-24-45U UNIT DIMENSION DRAWING 15
XI) PT-24-95U UNIT DIMENSION DRAWING 16

Questions and Answers

  • J
    Jessica LeeAug 11, 2025
    Why does my Phase 3 Battery Charger continue charging at 3 amps or more?
    • C
      christine53Aug 11, 2025
      If your Phase 3 Battery Charger continues to charge at 3 amps or more without tapering back, it might be due to a D.C. load connected to the batteries drawing current. To check this, turn off the main battery switch to the D.C. electrical panel or switch off all D.C. loads to see if the charger outputs minimal amperage to fully charged batteries. Another possible cause is a bad cell in one of the batteries. For wet lead-acid batteries, use a hydrometer to check for a shorted cell. Consult the manufacturer for testing maintenance-free batteries.
  • R
    Rachael WilliamsAug 19, 2025
    How to troubleshoot Phase 3 Battery Charger when batteries are not fully charging?
    • C
      Cory HarveyAug 19, 2025
      If your Phase 3 Battery Charger's batteries are not reaching full charge, there could be several reasons. First, the batteries might be extremely discharged, requiring a longer recharge time. In this case, turn off all D.C. loads and allow the charger 24-48 hours to recharge the batteries. Another reason could be that the charger is limiting its output due to overload or over-temperature conditions. Try reducing the D.C. load and check for the cause of the over-temperature condition. Also, check the fan to ensure there is no blockage at the fan intake on the bottom of the charger. If the fan isn't working, replace it.
  • J
    Jose CarterAug 27, 2025
    Why is there high voltage across the Phase 3 Battery Charger output terminals?
    • N
      nielsenmichaelAug 27, 2025
      If you measure high voltage across the output terminals of your Phase 3 Battery Charger, it could be due to a couple of reasons. First, ensure that the batteries are properly connected to the charger. It's normal to see a slightly higher voltage (about 1/2 volt) across the output bank when no batteries are connected. Check for a tight connection of the charging leads to the batteries. Second, the equalize function might be activated. Verify the proper installation and operation of the equalize timer.
  • J
    James BeckerSep 3, 2025
    What to do if Phase 3 PT 80 Battery Charger won't stay in bulk/absorption phase?
    • M
      Mr. Omar Patel MDSep 3, 2025
      If your Phase 3 Battery Charger will not stay in the bulk/absorption phase when the re-initialize button on the remote panel is pressed, it might be because the batteries are already at or nearing a full charge. To verify proper operation, cycle the A.C. power off and on (or press the reinitialize button on the optional remote panel), then apply a large D.C. load.

Phase 3 PT 80 Specifications

General IconGeneral
BrandPhase 3
ModelPT 80
CategoryBattery Charger
LanguageEnglish