EasyManuals Logo

Phenix Technologies BK130 User Manual

Phenix Technologies BK130
39 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #5 background imageLoading...
Page #5 background image
BK-130
1-1
SECTION 1: TECHNICAL SPECIFICATIONS
Input
110 - 120 volts, single phase 50 / 60 Hz, 30 amperes
OR
208 - 240 volts, single phase 50 / 60 Hz, 15 Amperes
(Refer to Serial Tag for voltage and current designation)
Output Rating
0-36 kilovolts, 180 milliamperes
0-130 kilovolts, 50 milliamperes
Duty Cycle Capacitive Loading
5 minutes ON/15 minutes OFF @ 50 mA / 180 mA
1 hour ON/1 hour OFF @ 33.3 mA / 120 mA
Continuous @ 25 mA / 90 mA
Type of Cooling
ONAN (Oil / Air Natural Convection)
Operating Ambient Temperature
10 40 degrees C
Output Termination
2” Polished Ball 36 kV
3” x 12” High Voltage Spinning – 130 kV
Metering - Digital
Output Voltmeter: 3 ½ Digit LCD, Accuracy ±(0.8% of reading + .2% of range)
Output Currentmeter: 3 ½ Digit LCD, Accuracy ±(0.8% of reading + .2% of range).
4 Ranges: 0-200µA, 2mA, 20mA, 200mA
Sizes and Weights
Control/Regulator Section: 21.25” (540mm) W x 16.75" (426mm) D x 13.75" (350mm) H;
120V - 45 lbs. (20.4 kg), 220 V 50 lbs (22.7 Kg)
High Voltage Section: 16" (406mm) W x 16" (406mm) D; X 30” (762mm) H;
178 lbs. (80.7 kg)
Additional Equipment
Cart : 22.5” (572mm) W x 29.25” (743mm) D x 50” (1270mm) H;
61 lbs. (27.7 kg)
Cables: 20 lbs. (9.1 kg)
Total Unit Weight: 120V - 304 lbs. (137.9 kg), 220V 309 lbs. (140.2 Kg)

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Phenix Technologies BK130 and is the answer not in the manual?

Phenix Technologies BK130 Specifications

General IconGeneral
BrandPhenix Technologies
ModelBK130
CategoryTest Equipment
LanguageEnglish

Related product manuals