72
HUDSON 8
16
GENERAL PRODUCT SPECIFICATION(Continued)
Note: recommended at 5 to 35°C, Humidity less than 60 %
6.2 Transportation tests
Standard Philips UAN-D1400 NSTA
Height 67/25 cm 76.0 cm
1 face(btm-67cm) 1 corner
Drop Sequence 5 faces(others-25cm) 3 edge
Test Btm->Btm->Btm->L->F->Rt->Rr->Top (Room temp) 6 face
Electrical function ok
Test Mechanical function ok
Result No serious damage on set appearance
(Room temp 20°C~23°C, humidity 40%~65%)
(1) PACKAGING
Sequence 7 Hz, 1.05 G, 30 min. for transport direction only
(2) OPERATING
Vibration 7 Hz, 10.6 mm, 30 min. for transport direction only
Test Test Electrical function ok
Result Mechanical function ok
No serious damage on set appearance
For design evaluation only
Operating
10 G, 11 msec, 1000 cycles
Bump Temperature : 23°C
Tes t Humi d i t y : 60 %
Air pressure : 100 kpa
(According to DSD draft standard UAN-D636)
6.3 Display disturbances from external environment
According to IEC 801-2 for ESD disturbances
6.4 Display disturbances to external environment
6.4.1 EMI
EMI: FCC, VCCI, CE, C-Tick, MPRIII, BCIQ, IC, BSMI, *IEC60601-1-2 (EU)
* Medical compliance only applies for dedicated models.
7.0 Reliability
7.1. Mean Time Between Failures
System MTBF (Including the LCD panel and CCFL) : 50,000 hrs
8.0 Quality assurance requirements
8.1 Acceptance test
According to MIL-STD-105D Control II level
AQL: 0.4 (major)
1.5 (minor)
(Please also refer to annual quality agreement)
Customer acceptance criteria: UAW0377/00
9.0 Serviceability
The serviceability of this monitor should fulfill the requirements, which are prescribed in UAW-0346
and must be checked with the checklist UAT-0361.
10.0 Philips’Flat Panel Monitors Pixel Defect Policy
BRAND : PHILIPS
19 inch LCD Monitor
TYPE : 190CW8
2007-08-01
590