244E2 LCD 3
Technical Data
AUO
Type NR. : AUO M240HW01 V2
Resolution : 1920x1080 (Full HD)
Outside dimensions
: 556.0(H) x 323.2(V) x 16.35(D)
Typ
Pitch (mm) : 0.276mm x 0.276mm
Color pixel
arrangement
: 1920 horiz. By 1080 vert
Display surface
: Hard coating (3H), Anti-glare
treatment
Color depth : 16.7M (8-bit with A-FRC)
Backlight : 4 CCFL
Active area (W x H) : 298.8 (H) ×531.36 (V) mm
View angle (CR=10) : >=150 for Right/Left (Typ)
: >=140 for Up/Down (Typ)
Contrast ratio : >=1000:1 (Typ)
White luminance : 300 (center,Typ)
Color gamut : >=72%
Gate IC : Raydium / Novatek
Source IC : Raydium / Novatek
Response time : 5 ms (Typ)
Vertical frequency
range
: 50~75Hz
Scanning frequencies
Hor.: 30 – 83 K Hz
Ver.: 56 - 76 Hz
Video dot rate: D-sub < 205 MHz ; DVI < 165 MHz;
HDMI <165MHz
Power input: 90-264 V AC, 50/60 r 2 Hz
Power consumption: Normal on: < 48 W (max)
Functions:
(1) D-SUB analog R/G/B separate inputs, H/V sync
separated, Composite (H+V) TTL level, SOG sync.
(2) DVI digital Panel Link TMDS inputs.
Ambient temperature: 0
C
Power input connection
Power cord length : 1.8 M
Power cord type : 3 leads power cord with protective earth plug.
Power management
The monitor must comply with the Microsoft On Now
specification, and meet EPA requirements.
Mode HSYN
C
VSYN
C
Video Pwr-con
s.
Indicatio
n
Rec
.
tim
e
Power-O
n
On On active < 48 W
(max.)
White LED --
Blinking
White LED
Power
Saving
Off Off blanke
d
< 0.5W
Period: 3sec
On, 3sec Off
<3s
DC
Power
Off
ʳʳ N/A < 0.5 W LED Off ʳ
PIN No. SIGNAL PIN No. SIGNAL
1 Red 9 DDC +3.3V or +5V
2 Green/ SOG 10 Logic GND
3 Blue 11 Sense (GND)
4 Sense (GND) 12 Bi-directional data
5 Cable Detect (GND) 13 H/H+V sync
6 Red GND 14 V-sync
7 Green GND 15 Data clock
8 Blue GND
ʳʳ
PIN No. Description PIN No. SIGNAL
1 R T.M.D.S. data2 13 No Connect
2 T.M.D.S. data2+ 14 +5V Power
3 T.M.D.S. data2
shield
15 Ground (for +5V)
4 No Connect 16 Hot plug detect
5 No Connect 17 T.M.D.S. data0-
6 DDC clock 18 T.M.D.S. data0+
7 DC data 19 T.M.D.S. data0
shield
8 No Connect
20 No Connect
9 T.M.D.S. data1-
21 No Connect
10 .M.D.S. data1+
22
T.M.D.S clock
shield
11 T.M.D.S. data1
shield
23 T.M.D.S. clock+
12 No Connect
24 T.M.D.S. clock-
PIN No. Description PIN No. SIGNAL
1 TMDS Data2+ 11 TMDS Clock Shield
2 TMDS Data2 Shield 12 TMDS Clock-
3 TMDS Data2- 13 CEC
4 TMDS Data1+ 14 NC
5 TMDS Data1 Shield 15 SCL
6 TMDS Data1- 16 SDA
7 TMDS Data0+ 17 DDC/CEC Ground
8 TMDS Data0 Shield
18 +5V Power
9 TMDS Data0-
19 Hot Plug Detect
10 MDS Clock+
Susceptibility of display to external environment
Operating
- Temperature : 0 to 35 degree C
- Humidity : 80% max
- Altitude : 0-3658m
- Air pressure : 600-1100 mBAR
Storage
- Temperature : -20 to 60 degree C
- Humidity : 95% max
- Altitude : 0-12192m
- Air pressure : 300-1100 mBAR
Note: recommend at 5 to 35qC, Humidity less than 60 %