Reference : SGP_AVS_SW_ATLAS-05-05 Classification : COMPANY RESTRICTED
Version : 0.17 Project : ATLAS_DSW
Status : Proposed Chapter : User Manual
Date : 2006-09-12
Section : Diagnostic Software (Leco+)
© Philips Electronics N.V. 2006 Philips Semiconductors Page 68 of 124
Nucleus Name
DS_SYS_DivxModelIdSet
Nucleus Number 1240
Description Sets the Divx Model Id in NVRAM.
Technical - Initialize the NVM interface.
- Read the NVRAM CONFIG section into RAM
- Store the Divx model id into the CONFIG section in RAM
- Validate the CONFIG section in RAM
- Write the CONFIG section in RAM back into the non-volatile storage.
Execution Time Less than 2 seconds
User Input - 16-bit word containing the 12-bit Divx model Id.
- For example :
o 0x3031 (means Low Byte : 0x30 and High Byte 0x31)
Error Number Description
124001 Validate CONFIG section failed
124002 Cannot read CONFIG section
124003 Invalid user parameters
124004 Error initializing NVRAM interfaces
Example
DS:> 1240 0x3031
124000:
Test OK @
1
Nucleus Name
DS_SYS_DivxModelIdGet
Nucleus Number 1241
Description Retrieves the Divx Model Id from NVRAM.
Technical - Read the CONFIG section from NVRAM
- Check the header information of the CONFIG section to ensure that it is
Version 4
- If Version 4 is detected, proceed to read and display the High Byte and
Low byte of the Divx Model Id.
Execution Time Less than 2 seconds
User Input None.
Error Number Description
124101 Section version not Version 4
124102 Cannot read CONFIG section
124103 Error initializing NVRAM interfaces
Example
DS:> 1241
124100: Divx model id high byte = 0x31, low byte = 0x30
Test OK @