Reference : SGP_AVS_SW_ATLAS-05-05 Classification : COMPANY RESTRICTED
Version : 0.17 Project : ATLAS_DSW
Status : Proposed Chapter : User Manual
Date : 2006-09-12
Section : Diagnostic Software (Leco+)
© Philips Electronics N.V. 2006 Philips Semiconductors Page 67 of 124
Nucleus Name
DS_SYS_GLinkWriteRead
Nucleus Number 1238
Description Send out some data through the G-Link UART and read back the data.
The user must short-circuit the TX and RX line of the G-Link connector.
Technical - UART 3 setup (1200, 8, n, 1)
- Send “HELLO”.
- Receive data.
- Compare data with “HELLO”.
Execution Time 1 second
User Input None
Error Number Description
123800 Writing and reading back data through the G-Link succeeded
123801 Unable to setup the G-Link UART
123802 Failed to write data to the the G-Link connector
123803 No data was received from the G-Link connector
123804 Invalid data was received from the G-Link connector
Example
DS:> 1238
123800:
Test OK @
1
Nucleus Name
DS_SYS_LowPowerStandby
Nucleus Number 1239
Description Send wakeup reason to ASP and set the set to low power standby.
Technical - Set up ASP
- Send wakeup reason to ASP
- Send low power standby command to ASP
Execution Time Vary (Maximum time will depend on the relative timer used)
User Input - wakeup reason - the wakeup reason for the DB to power up
- timer - relative timing for the DB to power up if wakeup reason 1 or 3 is
chosen
Error Number Description
123901 Invalid data was given by the user
123902 Failed to communication to ASP
Example
DS:> 1239
Wakeup reason from Low Power Standby
1) timer only
2) local key or RC pressed only
3) any reason
or press 'a' to abort
1
Enter time to wake up from low power standby.
Range 1 - 5 mins:
1
Entering low power standby
2