PHILIPS 4000 03 OPERATING LOGIC
5/8
3.7. Coee cycle
Main switch ON START STOP
Time
Coee grinder
Heating
Pump
Brewing unit gear
motor
Status
Heating Ready Coee cycle
Time
(Dosage)
Pump operation (ow
meter pulses) in
accordance with the
amount of product
selected.
approx.
45 sec.
*
Notes: * Only with Pre-brewing
Status
Microswitch
(gear motor)
OFF
ON
Coee cycle
1. e coee grinder starts the grinding process (controlled by Time);
2. e gear motor (brewing unit) moves to the brewing position;
3. Preliminary dispensing phase (short pump activity, short pause);
3.1. Solenoid valve opening (For products: Cappuccino and Frothed Milk);
3.2. Dispensing Milk (For products: Cappuccino and Frothed Milk);
3.3. Solenoid valve closing (For products: Cappuccino and Frothed Milk);
4. Coee dispensing (the pump operation period is dened by the amount of product dispensed);
5. e gear motor moves to its home position (the dregs are expelled automatically);
Note: For the product cafè au lait, the dispensing of the milk takes place after that of coee.