Service Modes, Error Codes, and Fault Finding
EN 36 SDI PDP5.
Figure 5-14 Fault symptom: “Abnormal Display”
Abnormal Display
Exept for Horizontal or Vertical Lines
Check FFC
(Flat Foil Cables) between
Logic-main, X-main and Y-main
Logic-Main
Observation of
abnormal Display
Y-Main Check
Check Fuses and FET
X-Main Check
Check Fuses and FET
Regular abnormal
pattern
Logic main
normal state
Replace PDP
Ye s
No
Replace the Logic-
main board
Check X
Waveform
Check Ramp
waveform on Y-board
(buffer)
1
2
3
Waveform?
Go to X-Main board
Check
Check voltages.
Adjust Y waveform
Check voltages.
Replace Y-Main
board
Not
correct
Waveform is
OK
No
waveform
Waveform?
X main board seems to be OK.
Check supply voltages or
replace X-Main board.
Replace X-Main
board
Not
correct
Waveform is
OK
Waveform not
OK
Replace PDP