VARILITE® - VL1000™ ERS LUMINAIRE SERVICE MANUAL
38 14-May-2009 02.9663.0010 F
Shutter Blade or Rack Replacement
Parts:
as required:
BLADE, SHUTTER, COATED SIDE A (12.9663.1323)
BLADE, SHUTTER, COATED SIDE B (12.9663.1324)
RACK, SHUTTER (10.9663.1314)
Tools:
#2 Phillips screwdriver
To remove and replace a shutter blade or rack:
Step 1. Disconnect luminaire AC input cable from power source.
Step 2. Remove shutter assembly. Refer to “Shutter Assembly Replacement” on
page 36.
Step 3. Place shutter assembly on work bench, motor side down. Remove four
6-32x1/4" PFS screws and remove cover plate (Figure 2-16).
Figure 2-16: Shutter Assembly Breakdown
6-32x1/4" PFS Screw
Shutter
Layer 1
Layer 2
Layer 3
Layer 4
Separator
Spacer
Cover
Rack (x8)
6-32x1/4"
PFS Screw
Spacer
Spacer
Spacer
Separator
Stiff Separator
Separator
Stiff Separator
Stiff Separator
Separator
Separator
Assembly
Beveled Blade
Straight Blade
Beveled Blade
Straight Blade
Do not touch shutter blades with bare
fingers. Clean with soft cloth if touched.
CAUTION:
Cover Plate