oscilloscope. There are a number of commands required to set up, trigger, capture, and download the sampled
traces and so the reader is advised to install the application package and study the Python 3 code for the two
channel digital oscilloscope.
Specifications
Input voltage range: ±12V
Input bandwidth: 370Khz
Input Impedance: 1Mohm
Maximum sample rate - 1 channel: 1 Msample/sec
Maximum sample rate - 2 channel: 500 Ksample/sec
Trace buffer size: 1024 samples
Resolution: 12 bits
Trigger Jitter: ±2μsec max
Connections
Use Analog Input terminal 1 for Oscilloscope Channel 1 and terminal 5 for Channel 2. Ground both signals
using terminal 9:
Commands
The arguments used in the Oscilloscope commands are:
addr: the address of the DAQC2plate board being addressed. This can be 0-7 and is set via the
address selection header described above
C1: input channel 1 enable. This can take on the value of 0 or 1.
C2: input channel 2 enable. This can take on the value of 0 or 1.
rate: per channel sample rate of A/D converter. The valid values in samples/second are:
0: 100
1: 200
2: 500
3: 1000
4: 2000
5: 5000
6: 10,000
7: 20,000
8: 50,000
9: 100,000
10: 200,000
11: 500,000