EasyManua.ls Logo

Piazzetta 600HT - Chimney Fires; Door Operation

Piazzetta 600HT
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
English
6
H07024510 / DT2000575 - Rev. 00
Extractor fan
T
here must not be an extractor fan fitted in the same room as the stove as this can cause the stove to
emit smoke and fumes into the room.
Aerosol sprays
Do not use an aerosol spray on or near the stove when it is alight.
Use of operating tools
Always use the operating tools provided when handling parts likely to be hot when the stove is in use.
Chimney Fires
If the chimney is thoroughly and regularly swept, chimney fires should not occur. However, if a chimney
fire does occur turn the air control setting to the minimum, and tightly close the doors of the stove. This
should cause the chimney fire to go out in which case the control should be kept at the minimum setting
until the fire in the stove has gone out. The chimney and flueways should then be cleaned. If the chimney
fire does not go out when the above action is taken then the fire brigade should be called immediately.
After a chimney fire the chimney should be carefully examined for any damage. Expert advice should be
sought if necessary
Permanent air vent
The stove requires a permanent and adequate air supply in order for it to operate safely and efficiently.
In accordance with current Building Regulations the installer may have fitted a permanent air supply vent
into the room in which the stove is installed to provide combustion air. This air vent should not under any
circumstances be shut off or sealed.
HETAS Ltd Approval
Please note that HETAS Approval only covers the use of wood on the stove and approval does
not cover the use of other fuels either alone or mixed with other fuels, nor does it cover
instructions for the use of other fuels.
USER OPERATING INSTRUCTIONS - WOOD
The instructions detailed in the section / in the instruction booklet should be followed.
Door operation
Describe door operation and use of the tool to open and close the doors, if appropriate.
Lighting of fire
Place some firelighters or paper and dry kindling wood on the grate and cover with a small amount of fuel.
Set air controls to maximum and set light to firelighters or paper. Close the doors and allow fire to burn
until fuel is well alight then load with more fuel and adjust air controls to the required level of heat output.
Before relighting the fire clean the firebed of excess ash and clinker and empty the ashpan.
Refuelling
Keep the firebox well filled (the fuel may be sloped up from the front firebars), but do not allow fuel to spill
over the top of the front fire bars. Take care that fuel does not project over the front fire bars or damage
to the glass may be caused when the doors are closed