These data are obtained using beech wood with moisture content below 20% and with intervals between stoking-up of approximately one hour.
Use of this appliance is intermittent.
Technical data with closed grate for flue calculations
H07020660 / DT2000245 - Rev. 03
36
English
DT2010880-01
2.5 Technical data
U.M.
e902 e905
Rated heat output kW 7.4 7.4
Consumption at rated heat output kg 1.4 1.4
Thermal efficiency % 84.5 84.5
CO content (with 13% O2) % 0.09 0.09
Approved in accordance with standard - EN 13240 EN 13240
T
est report No.
-
C
PD-10-007
C
PD-10-007
Flue diameter cm Ø14 Ø14
Hearth opening (WxH) cm 30x27 30x27
Grate surface area cm
2
1000 1000
Weight kg 170 125
Fresh air intake (recommended minimum section) cm
2
100 100
U.M.
e902 e905
Rated heat output kW 7.4 7.4
Smoke flow rate g/s 6.9 6.9
Average temp. of smoke in the flue °C 254.0 254.0
Minimum draught Pa 12 12