5.0 TROUBLESHOOTING
DT2010069-00
H07020660 / DT2000245 - Rev. 03
44
English
Some of the above problems could be resolved by following the instructions. Only qualified persons must carry out work on the
stove and only when it is cold.
Unauthorised tampering with the appliance or use of other than original spare parts invalidates the warranty and relieves the
m
anufacturer of all and any liability.
The manufacturer shall not be liable for any problems caused by lack of or inefficient maintenance or by failure to comply with the
instructions in the product installation and operating guide.
P
roblem Cause Remedy
The window becomes
excessively dirty
Lack of draught Check the smoke/gas discharge pipe
W
et wood
Use dry wood
Use of mediocre or poor class fuels
Change the type of fuel
(See “Fuel” paragraph)
Not enough combustion air Open the air dampers further
Condensation forms
Section of flue too large
Reduce the section by inserting a well
insulated pipe with suitable section
inside the flue
Flue not adequately insulated
Clad the flue with hollow tiles or
other insulating materials
Slow combustion and therefore low
smoke temperature
Burn smaller and dry logs.
Open the primary air damper further
Difficulty in lighting Closed air damper
Put the combustion air (intake)
dampers to maximum position
Logs too large
Use smaller logs
Wood too wet
Burn drier wood
Lack of draught Check the smoke/gas discharge pipe