EasyManua.ls Logo

Pilz PNOZ e3vp - Unit Features; Safety Features; Block Diagram;Terminal Configuration

Pilz PNOZ e3vp
35 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PNOZ e3vp
Operating Manual PNOZ e3vp
21244-EN-04
8
Unit features
} Outputs using semiconductor technology:
– 1 safety output, either instantaneous or delayed
– 1 safety output, delayed
– 1 auxiliary output
– 2 test pulse outputs
} Connection options:
– Safety sensors PSEN2.1p-10 and PSEN2.1p-11
– Position switch with N/C / N/O combination
} Selectable delay time
} LED display for:
– Supply voltage
– Switch state of safety outputs
} 2 logic inputs (AND/OR) for logic connections between several units
} Feedback loop for monitoring external contactors
} Detection of shorts across contacts via test pulse outputs
Safety features
The relay meets the following safety requirements:
} The circuit is redundant with built-in self-monitoring.
} The safety device remains effective in the case of a component failure.
} The safety outputs are tested periodically using an off-test.
Block diagram/terminal configuration
Input
&
Feed-
back
Diag-
nostic
Power
Test
Pulse
Output
S12
S35
S36
Y6
Y5
S11 S23 14 24Y32
A1 A2
S24 Y7
Input
Y4
Start
S34
t
t