Technical details
N° pedido 774140 - 774142
See below for more order numbers
General 774140 774141 774142
Approvals
CCC, CE, EAC (Euras-
ian), TÜV, cULus Listed
CCC, CE, EAC (Euras-
ian), TÜV, cULus Listed
CCC, CE, EAC (Euras-
ian), TÜV, cULus Listed
Electrical data 774140 774141 774142
Supply voltage
Voltage 24 V 42 V 48 V
Kind AC AC AC
Voltage tolerance -15 %/+10 % -15 %/+10 % -15 %/+10 %
Output of external
power supply (AC) 7 VA 7 VA 7 VA
Frequency range AC 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz
Duty cycle 100 % 100 % 100 %
Inputs 774140 774141 774142
Number 2 2 2
Voltage at
Input circuit DC 24 V 24 V 24 V
Current at
Input circuit DC 40 mA 40 mA 40 mA
Max. overall cable resist-
ance Rlmax
Single-channel at UB
AC
80 Ohm 80 Ohm 80 Ohm
Dual-channel without
detection of shorts
across contacts at UB
AC 160 Ohm 160 Ohm 160 Ohm
Dual-channel with de-
tection of shorts across
contacts at UB AC 10 Ohm 10 Ohm 10 Ohm
Relay outputs 774140 774141 774142
Number of output con-
tacts
Safety contacts (N/O),
instantaneous 8 8 8
Auxiliary contacts (N/C) 1 1 1
Max. short circuit current
IK 1 kA 1 kA 1 kA
Utilisation category
In accordance with the
standard EN 60947-4-1 EN 60947-4-1 EN 60947-4-1