Hunter-Pro Series Captain 8 - Installation Guide
60
7 Key #4: Timers, Counters
See the menu screens, starting page 93.
7.1. Entry/Exit delays
Set the entry delay 1 and 2 and the exit delay, in seconds (max. 250). Press [NEXT] to set the
next delay. To use entry delay 2 per zone, see parameter “T” on page 47.
7.2. Output type timers
Set the timers of the output types that trigger the physical outputs. These timers set the output’s
trip time. The timers operating options are listed in the next table see section 10.2, on page 65 for
more details on output types.
The output type is activated...
For as long as the panel is armed
For as long as the event that had triggered it has not been restored. For
example, the phone (line) fault output type can trigger a relay, which
will be tripped for as long as the line is faulty.
The following table lists the output types that have timers and their default times.
* This output type is triggered when a physical output is activated by telephone.
** This output type is triggered when the alarm system is disarmed and the last open zone is
closed. When countdown expires, the assigned physical output can be used for energy saving
- turning off the lights, for example.
7.3. AC report delay
Set a time (in minutes, max. 250) to delay AC fault reports. The default is 15 min.