24 VAC (INPUT)24
VAC
(INPUT)
(CONTROL X'FER)
(HEAT DEMAND)
TWISTED
20 AWG
1
J11
32
J8
6BK
7
8BR
W/BR
4GY
11
V
5BK
9
O
10
Y
BK
GY
2
W/BK
12
1W
C
S1
3R
R
GY W/BK
351
R
62
OFF
C
ON
START
Y
(OPTIONAL)
Y
8
Y
24 VDC
24
VDC
A1
(LEFT B/L)
SEE NOTE 8
SEE
NOTE
8
GY
Y
C
NO
C
1W/BR W/BR
6
2
BR
BR
NO
NC
VDC
C
W/BRW/BR 1
NO
BL
O
R
2
5
3
24
VDC
O3
O
5
4
V
Y
V
Y
J20P20
K3
24
BR
J12
NC
Y
6
4
K4
K6
NC
NO
BK
6
BR
PROBE
4
9
5
7
(RIGHT B/L)
24 VDC
24
VDC
24 VDC24
VDC
GY
O
(COMMON)
24 VDC
24
VDC
24 VDC24
VDC
V
R
GY
V
BL
O
J10
3
2
PROBE
24 VAC
24
VAC
W
BR
1
W
V
BK
P10
BL
24
VDC
S7
C
BLANCH ON
BLANCH
ON
BLANCH OFFBLANCH
OFF
GY
O
K5
NC
C
R
VDC
24
W/BR
W/BR
BR
TWISTED
20 AWG
BK
BK
Y
GY
V
BL
O
7
8
J8
5
6
10
4
11
12
9
WGY
4
J27
GY
OW/BK
R
W/BK
W
351
62
3
2
1
FRONT PANEL, PITCOMATIC COMPUTER OPTION ONLYFRONT PANEL,
PITCOMATIC
COMPUTER
OPTION
ONLY
PITCOMATIC
COMPUTER
CONNECT TO P11CONNECT TO
P11
CONNECT TO P27CONNECT TO
P27
CONNECT TO P8CONNECT TO
P8
COMPUTER WITHCOMPUTER
WITH
BASKETLIFT OPTION ONLYBASKETLIFT OPTION
ONLY
CONNECT TO P12CONNECT TO
P12
CONNECT TO P27CONNECT TO
P27
CONNECT TO P8CONNECT TO
P8
SH OFSH
OF
SCALE:SCALE:
INC. AND MAYNOT BE REPRO-INC. AND
MAY NOTBE
REPRO-
DUCED , COPIED, OR DISSEM-DUCED , COPIED,
OR DISSEM-
INATED TOTHIRD PARTIESINATEDTO THIRD
PARTIES
WITHOUT THE WRITTEN PERMIS-WITHOUT THE
WRITTEN
PERMIS-
PITCO FRIALATOR INC.PITCO
FRIALATOR INC.
CONCORD, NH 03301 U.S.A.CONCORD,
NH
03301 U.S.A.
SION OF:SION
OF:
D
SIZE DWG NO:DWG
NO:
THE INFORMATION CONTAINEDTHE
INFORMATION
CONTAINED
ON THIS DOCUMENT IS THEONTHIS
DOCUMENT IS THE
PROPERTY OF PITCO FRIALATORPROPERTY OF
PITCO FRIALATOR
PAR T N O:PART NO:
REV
9. 120 VAC MODELS: CONNECT BLACK LEAD TO PIN 3 ON T1 AND T29.
120
VAC
MODELS:
CONNECT BLACK
LEAD TO
PIN
3
ON T1 AND T2
12. FOR MODEL 7, OMIT S5, M1, AND TM2 OR K4.12.
FOR
MODEL 7,
OMIT S5,
M1, AND TM2
OR
K4.
13. A CONTINUOUS GREY WIRE IS CONNECTED BETWEEN P43 PIN 9 AND K5 WHEN THE13. A CONTINUOUS
GREY WIRE
IS
CONNECTED
BETWEEN
P43
PIN
9 AND
K5
WHEN THE
BLANCH SWITCH S7 IS NOT PRESENT (3600 OPTION).BLANCH
SWITCH
S7
IS
NOT PRESENT (3600
OPTION).
11. CONNECT ELECTRONIC IGNITION (A2) TO FLAME SENSOR (E1) WITH WIRE ASSEMBLY (P5045113)11.
CONNECT ELECTRONIC
IGNITION
(A2) TO
FLAME
SENSOR
(E1)
WITH
WIRE ASSEMBLY (P5045113)
YELLOW WIRE FROM S2 TO P14-6. TAPE OFF REMAINING LEAD TO S1 AND P14-3.YELLOW
WIRE
FROM
S2 TO
P14-6. TAPE
OFF
REMAINING
LEAD TO
S1 AND
P14-3.
10. IF "NO BACK-UP THERMOSTAT" OPTION IS SPECIFIED, OMIT S2 AND10.
IF
"NO
BACK-UP THERMOSTAT"
OPTION
IS
SPECIFIED,
OMIT S2 AND
220, 240 VAC MODELS: CONNECT BLACK LEAD TO PIN 1 ON T1 AND T2220,
240
VAC
MODELS:
CONNECT BLACK
LEAD TO
PIN
1
ON T1 AND T2
1. A CONTINUOUS GREY WIRE IS CONNECTED BETWEEN P7 PIN 1 AND 21. A CONTINUOUS
GREY WIRE
IS
CONNECTED
BETWEEN
P7
PIN
1 AND
2
WHEN NEITHER THE FLOAT SWITCH S4 NOR THE DRAIN SWITCH S8 IS PRESENT.WHEN
NEITHER THE
FLOAT SWITCH
S4
NOR THE
DRAIN
SWITCH
S8
IS
PRESENT.
5. DESIGNATION OF RIGHT AND LEFT BASKETLIFT MOTOR AS VIEWED FROM FRONT OF FRYER5.
DESIGNATION
OF
RIGHT AND
LEFT BASKETLIFT MOTOR AS
VIEWED
FROM
FRONT OF
FRYER
2. AT FUSES F1 AND F2 USE FUSE HOLDER (P5045794).2. AT FUSES
F1 AND
F2
USE
FUSE
HOLDER
(P5045794).
3. CONNECT HI-LIMIT S12 TO VALVE V1 WITH WIRE ASSEMBLY (P5047625)3.
CONNECT HI-LIMIT S12 TO
VALVE
V1
WITH
WIRE ASSEMBLY (P5047625)
4. UNLESS OTHERWISE SPECIFIED ALL WIRES ARE 18 AWG4.
UNLESS
OTHERWISE
SPECIFIED ALL WIRES ARE
18 AWG
CORD (PP10615) - BROWN TO P1-3, BLUE TO P1-2, GREEN/YELLOW TO P1-1.CORD
(PP10615)
-
BROWN TO
P1-3,
BLUE TO
P1-2,
GREEN/YELLOW TO
P1-1.
7. 220, 240 VAC MODELS ONLY: P15 IS OMITTED. P1 IS WIRED TO 10 FT OF 14-3 POWER SUPPLY7.
220,
240
VAC
MODELS
ONLY:
P15
IS
OMITTED.
P1
IS
WIRED TO
10
FT OF
14-3
POWER
SUPPLY
6. 220 VAC UNITS ARE WIRED IDENTICALLY TO 240 VAC UNITS6.
220
VAC
UNITS ARE
WIRED
IDENTICALLY TO
240
VAC
UNITS
BLANCH SWITCH S7 IS NOT PRESENT (PITCOMATIC OPTION).BLANCH
SWITCH
S7
IS
NOT PRESENT (PITCOMATIC
OPTION).
8. A CONTINUOUS GREY WIRE IS CONNECTED BETWEEN P10 PIN 5 AND K5 WHEN THE8. A CONTINUOUS
GREY WIRE
IS
CONNECTED
BETWEEN
P10
PIN
5 AND
K5
WHEN THE
NOTES:
FRONT PANEL, T-STAT BEHIND DOOR OPTION ONLYFRONT PANEL, T-STAT BEHIND
DOOR
OPTION
ONLY
PROBE
A3
MELT
MELT
5
4
11
PROBE
14
RELAY (NC)
RELAY (NC)
6
J41
BL
11
P41
BL
BK
BL
BR
2 BK
10
12 BL
C
MELT ON
MELT OFF
S3
W
W
DS1
POWER ONPOWER
ON
12
RELAY (NO)
RELAY (NO)
10
POT (V)
POT (V)
7
RETURN
POT (O)
POT (Y)
9
8
24 VAC
24 VAC
13
RELAY (COM)
1
3
2
BK
V
GY
6
V1
4 BK
GY
Y
O
O5
Y3
BK
R
W
8 BK
7
W9
BK
TWISTED
20 AWG
W
GY
DS2DS2
HEATING
W
GY
4
J27