EasyManuals Logo

Pitco SELV14 User Manual

Pitco SELV14
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #21 background imageLoading...
Page #21 background image
INSTALLATION & OPERATIONAL SELV MANUAL
21 L20-406 Rev 5 (3/14)
7
8
4.19 ControlorTimer:(LeftsideofDualorSingleVat)
With display showing [PROGRAM], press the product key [0].
Display shows [SELECT] [OPTIONS].
Press product key 7; display will show [CONTROL].
Use the product key [0] to scroll through choices (Control, Timer).
Press [P] key to save choice. Display shows [PROGRAM].
Note: If timer is selected, heat control outputs are disabled, leaving only the timer
functions active. Do not make this selection on Solstice fryer models.
4.20 ControlorTimer:(RightsideofDualVat)
Note: This key has no function of single vat controls.
With display showing [PROGRAM], press the product key [0].
Display shows [SELECT] [OPTIONS].
Press product key 8; display will show [CONTROL].
Use the product key [0] to scroll through choices (Control, Timer).
Press [P] key to save choice. Display shows [PROGRAM].
Note: If timer is selected, heat control outputs are disabled, leaving only the timer
functions active. Do not make this selection on Solstice fryer models.
4.21 OTHERDISPLAYS:
[PROBE OP] [OPEN]
Open probe detection is standard on all Pitco controls. If probe is detected open, normal heating and
cooking activities are suspended.
[HIGH TMP] [HIGH TMP]
This display warns operators that the vat temperature has exceeded set temperature by 40°F (22°C), or an
absolute maximum of 410°F (210°C). This display does not show the status of the mechanical high limit
switch.
[DRAINING] [TURN OFF]
This message indicates that the drain valve has been opened, the vat is assumed to be empty by the
controller. Normal heat control activities are suspended. To restore to normal operation, close the drain
value. Display will show [TURN OFF] [TURN OFF].
Turn controller off, and refill the vat. Continue with normal operations at (See section 4.6).
[HEAT] [FAILURE] OR [IGNITION] [FAILURE]
This message indicates that the heating system failed to respond. Typically, the high temperature limit
switch has tripped and is in need of resetting. In the case on gas fired appliances, this message will display
if the pilot fails to light or is detected marginal by the ignition module.
[SYSTEM] [FAILURE]
This message indicates a shorted probe. If probe is detected as a short circuit normal heating and cooking
activities are suspended.
4.22 APPLIANCESHUTDOWN
Refer to the following procedure to shutdown the appliance.
Press and hold the computer control
button to turn the controller OFF

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pitco SELV14 and is the answer not in the manual?

Pitco SELV14 Specifications

General IconGeneral
BrandPitco
ModelSELV14
CategoryFryer
LanguageEnglish

Related product manuals