Installation – Electrical connection oven
AMPS per phase and DECK (1) or OVEN (2) for ovens with – Power Guard, see (3) – Door Opener, see (4)
Model
230V 1ph + N 400V 3ph + N 480V 3ph + N
230V 3ph / 400V 3ph + N
200V 3ph 208V 1ph 208V 3ph 240V 1ph 240V 3ph 400V 3ph
460V 3ph
230V 3ph 400V 3ph + N (440-480)
(1) (1) (2) (1) (2) (1) (1) (2) (1) (1) (1) (1) (1) (1) (2) (1) (2)
PM 721
27.7 9.3
9.3
7.8
7.8
16.2 9.3
9.3
17.2 30.6 17.9 28.9 16.9 9.3
9.3
8.1
8.1
PM 722 18.6 14.9 18.6 18.6 16.1
PM 723 27.9 22.4 27.9 27.9 24.2
PM 724 27.9 + 9.3 22.4 + 7.8 27.9 + 9.3 27.9 + 9.3 24.2 + 8.1
PM 725 27.9 + 18.6 22.4 + 14.9 27.9 + 18.6 27.9 + 18.6 24.2 + 16.1
PM 731
41.2 13.9
13.9
11.6
11.6
24.1 13.9
13.9
25.6 45.6 26.6 43.3 25.1 13.9
13.9
12.0
12.0
PM 732 27.8 23.1 27.8 27.8 24.1
PM 733 41.7 34.7 41.7 41.7 36.1
PM 734 41.7 + 13.9 34.7 + 11.6 41.7 + 13.9 41.7 + 13.9 36.1 + 12.0
PM 735 41.7 + 27.8 34.7 + 23.1 41.7 + 27.8 41.7 + 27.8 36.1 + 24.1
PM 741
54.8 18.5
18.5
15.4
15.4
32.1 18.5
18.5
34.1 60.6 35.5 57.2 33.5 18.5
18.5
16.0
16.0
PM 742 37.0 30.8 37.0 37.0 32.1
PM 743 55.6 46.1 55.6 55.6 48.1
PM 744 55.6 + 18.5 46.1 + 15.4 55.6 + 18.5 55.6 + 18.5 48.1 + 16.0
PM 745 55.6 + 37.0 46.1 + 30.8 55.6 + 37.0 55.6 + 37.0 48.1 + 32.1
(1) Amps per phase and deck with 1 power supply cable per oven deck.
(2) Amps per phase and oven with 1 power supply cable per oven, up to 3 deck. If 4 and 5 deck, 2 power supply cables per oven is required.
(3) Power Guard reduce ovens Amp draw. Calculate sec. deck as 0 A. Simultaneously used master / sec. decks reduce the sec. decks capacity.
(4) Door Opener require 1 separate 3ph (208/230/400/480) supply. Supplies up to 5 deck. Amp draw 1 A / deck / phase.
CANADA VERSION -