Installation – Electrical connection oven
AMPS per phase and DECK (1) or OVEN (2) for ovens with – Power Guard, see (3) – Door Opener, see (4)
Model
230V 1ph + N 400V 3ph + N 480V 3ph + N
230V 3ph / 400V 3ph + N
200V 3ph 208V 1ph 208V 3ph 240V 1ph 240V 3ph 400V 3ph
460V 3ph
230V 3ph 400V 3ph + N (440-480)
(1) (1) (2) (1) (2) (1) (1) (2) (1) (1) (1) (1) (1) (1) (2) (1) (2)
PM 821
39.2 13.1
13.1
10.9
10.9
22.6 13.1
13.1
24.0 43.3 25.0 40.9 23.7 13.1
13.1
11.4
11.4
PM 822 26.1 21.7 26.1 26.1 22.6
PM 823 39.1 32.5 39.1 39.1 33.9
PM 824 39.1 + 13.1 32.5 + 10.9 39.1 + 13.1 39.1 + 13.1 33.9 + 11.4
PM 825 39.1 + 26.1 32.5 + 21.7 39.1 + 26.1 39.1 + 26.1 33.9 + 22.6
PM 831
58.6 19.6
19.6
16.2
16.2
33.9 19.6
19.6
36.0 – 37.5 61.2 35.4 19.6
19.6
16.9
16.9
PM 832 39.1 32.5 39.1 39.1 33.9
PM 833 58.7 48.7 58.7 58.7 50.8
PM 834 58.7 + 19.6 48.7 + 16.2 58.7 + 19.6 58.7 + 19.6 50.8 + 16.9
PM 835 58.7 + 39.1 48.7 + 32.5 58.7 + 39.1 58.7 + 39.1 50.8 + 33.9
PM 841
– 24.7
24.7
20.5
20.5
42.7 24.7
24.7
45.4 – 47.3 – 44.6 24.7
24.7
21.4
21.4
PM 842 49.3 41.0 49.3 49.3 42.7
PM 843 74.0 61.5 74.0 74.0 64.1
PM 844 74.0 + 24.7 61.5 + 20.5 74.0 + 24.7 74.0 + 24.7 64.1 + 21.4
PM 845 74.0 + 49.3 61.5 + 41.0 74.0 + 49.3 74.0 + 49.3 64.1 + 42.7
(1) Amps per phase and deck with 1 power supply cable per oven deck.
(2) Amps per phase and oven with 1 power supply cable per oven, up to 3 deck. If 4 and 5 deck, 2 power supply cables per oven is required.
(3) Power Guard reduce ovens Amp draw. Calculate sec. deck as 0 A. Simultaneously used master / sec. decks reduce the sec. decks capacity.
(4) Door Opener require 1 separate 3ph (208/230/400/480) supply. Supplies up to 5 deck. Amp draw 1 A / deck / phase.
CANADA VERSION -