Chapter 6. Troubleshooting
Q1: [VF-101G-KIT/VF-102G-KIT/VF-106G-KIT] Why didn’t the
monitor display anything or DVR record anything after
the analog camera, VF-10xG-KIT and cables are well
connected?
A: 1. Check the corresponding devices:
z The analog camera should connect to the VF-10xG-T
the video transmitter.
z The monitor / DVR should connect to the VF-10xG-R
the video receiver.
When you do the reverse way, the connection cannot
be established.
2. Check the link status LED:
z Check the cable connections of coaxial and ber patch
cord, and make sure both VIDEO and LINK LEDs are
lit.
z The optical interface of the VF-10xG-KIT is a single
mode and single ber bi-directional transceiver, and
make sure the ber patch cord applies to 9/125um
single mode.
Q2: [VF-101G-KIT/VF-102G-KIT/VF-106G-KIT] Can the
VF-10xG-KIT connect to other optic device to extend the
deployment distance? For example, the Media Converter or
Fiber Optic Switch.
A: No, the VF-10xG-T and VF-10xG-R must be used in pairs.
Although the VF-10xG-KIT uses a 1000Mbps single mode
transceiver as its optical interface, the encoded/decoded
video data does not comply with IEEE 802.3z 1000BASE-X,
so the packets are not able to be forwarded by media
converters or ber switches.