А.С.
CHARGING
UNIT
(Fig.17)
2.25
The
a.c.
charging
unit
enables
up
to
16
Clansman
3.3Ah
and
1Аһ
secondary
batteries
to
be
recharged
simultaneously,
regardless
of
their
state
of
discharge.
The
charging
procedure
is
as
follows:-
2.25.1
Remove
the
cover
from
the
charging
unit.
2.25.2
Adjust
the
voltage
selector
panel
(8)
to
correspond
with
the
voltage
of
the
50
-
60
Hz
a.c.
mains
supply
WARNING:
Ensure
that
the
unit
is
disconnected
from
44
the
supply
whilst
making
adjustments.
2.25.5
Remove
the
cover
from
the
a.c.
mains
fuse
(4)
and
ensure
that
it
is
of
the
correct
rating,
i.e.
20A for
a
100
-
125V
supply
and 10A
for
a
200
-
250V
supply.
2.25.4
.
Open
the
sliding
vent
at
the
rear
of
the
charging
unit.
2.25.5
Using
the
a.c.
charging
unit
supply
cable,
connect
the
INPUT
plug
(6)
to
the
a.c.
mains
supply.
2.25.6
Set
the
LAMPS
switch
(7)
down
(on).
20.25.7
Using
the
battery
charging
cables,
connect
the
charging
connector
of
each
battery
to
be
charged
to
an
outlet
connector
(5)
and
set
the
MAINS
switch
(5)
down
(on).
Each
outlet
has
an
associated
yellow
lamp
(1),
which
will
light
to
indicate
that
the
battery
is
properly
connected
and
is
being
charged.
When
the
battery
is
fully
charged
this
lamp
will
extinguish
and
an
associated
green
lamp
(2)
will
light.