EasyManua.ls Logo

Plessey PRC 320/1 - Functional Checks

Default Icon
99 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CHAPTER
THREE
PREVENTIVE
AND
CORRECTIVE
MAINTENANCE
AND
FUNCTIONAL
CHECKS
GENERAL
5.1
The
procedure
given
in
Part
1,
Chapters
Four
and
Five
are
generally
applicable
to
the
PRC320/1-100W,
with
the
exception
that
the
RT220/1
antenna
tuning
unit
is
inoperative
and
thus
its
meter
does
not
indicate
antenna
current.
This
function
is
performed
by
the
РУ1511
meter
when
the
OUTPUT
POWER
switch
is
set
to
FWD.
and
the
function
switch
to
DRIVER.
The
RT320/1
is
still
operative
when
BATT
CHK
is
selected,
however,
and
can
be
used
to
check
the
RT320/1
supply
voltage,
regardless
of
whether
this
is
derived
from
a
battery
or
the
PV1518.
FUNCTIONAL
CHECK
5.2
Before
checking
the
operation
of
the
additional
PRC320/1-100W
equipment,
carry
out
the
procedures
given
in
Part
1,
Chapters
Four
and
Five,
to
ensure
satisfactory
operation
of
the
RT320/1.
Monitoring
of
the
100W
equipment
performance
is
provided
by
the
PV1511
meter
and
its
associated
OUTPUT
POWER
switch,
the
four
positions
of
which
provide
meter
indications
as
follows:-
5.2.1
В.Е.
INPUT
-
the
drive
level
from
the
RT320/1,
which
should
be
approximately
30W
peak.
5.2.2
FWD.
-
the
forward
output
power
into
the
antenna,
which
should
be
between
80W
and
140W,
depending
on
the
supply
voltage,
when
the
antenna
is
accurately
matched.
85