3.3 DC Current
Range
Accuracy
Resolution Ration
2 mA
±(1.5% + 3)
1 μA
20 mA
10 μA
200 mA
100 μA
10A
±(2.0% + 5)
10 mA
Maximum input current: 10 A (not more than 10 seconds)
Overload protection: 0.2 A / 250 V fuse (10 A range is without insurance)
3.4 Resistance
Range
Accuracy
Resolution Ration
200 Ω
±(1.0% + 5)
0.1 Ω
2 kΩ
±(0.8% + 3)
1 Ω
20 kΩ
10 Ω
200 kΩ
100 Ω
2 MΩ
±(1.0% + 15)
1 kΩ
Overload protection: 250 V DC and AC peak
3.5 Diode and Continuity Test
Range
Display
Test Conditions
The diode forward voltage
DC current is about 1 mA
Reverse voltage: 3 V
Buzzer sound Test
Resistance smaller than (20
±1) Ω
Circuit starting voltage:
about 3 V
Overload Protection: 250 V DC or AC peak