(4)
PDP switching temperature
(5)
PDP Alarm offset
(6) Heatless backup mode (see note *)
(7)
Not activated
(8)
Modify
*: not applicable.
The screen shows the list of all settings.
Press the Enter button (2); a red selection bar is covering the first item (PDP extended cycle).
Use the ↓ key of the Scroll keys to select the setting to be modified and press the Enter key.
A pop-up screen appears. Use the ↑ or ↓ key to select the required parameter and press the Enter key
to confirm.
Regulation settings:
PDP extended cycle: the cycle is lengthened by putting the vessel in waiting mode (standby) if PDP
is low enough after regeneration and cooling. The extended cycle should only be activated when a
working PDP sensor is present.
PDP switching temperature: the PDP should not increase to this setting before the vessels are
switched when the dryer is in standby mode.
PDP Alarm offset: the PDP alarm is active when: PDP > PDP_switching_temperature +
PDP_alarm_offset. In that way, the alarm threshold can be set independently of the switching
threshold.
Automatic restart
Select the Automatic restart settings icon as described above and press the Enter button (2).
Following screen appears:
Text on figure
(1)
Automatic restart (Not Activated)
(2)
Maximum power down time
(3)
Restart delay
(4)
Modify
The screen shows the list of all settings.
Press the Enter button (2); a red selection bar is covering the first item (Automatic restart).
Use the ↓ key of the Scroll keys to select the setting to be modified and press the Enter key.
Instruction book