12
2.3 Going through self-tests and background calibration
During self-tests procedures the display first shows message with
firmware version [P-X.X],
message bAtt” and remaining battery power in relative units on the analog
scale.
Then the message “tESt” is displayed and the unit will perform its self-
test procedures.
After the self-tests are completed the instrument goes to the
background calibration. Message CAL (calibration) is activated on the
display during this process, the instrument measures radiation background
and calculates threshold values using the specified values of the n coefficients.
When self-tests and background calibration are finished, the PM1401MA is ready for
operation.
2.4 Operation Modes
In order to meet the demands of every user, PM1401MA can be customized according
to the user’s requirements by means of enabling/disabling various instrument settings and
operation modes. The following operation modes and options are available for the regular
PM1401MA:
Search Mode designed mainly for detection and location of gamma radioactive
sources. The readings of the instrument’s gamma detector are displayed in counts per second
(s
-1
) and the search algorithm based on background calibration is used;
Measurement Mode designed for measurement of the dose rate of gamma
radiation. In this mode the instrument alarms only in case the safety thresholds is exceeded;
To toggle between various operation modes, the MODE button is used.
2.4.1. Search Mode

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Polimaster PM1401MA and is the answer not in the manual?

Polimaster PM1401MA Specifications

General IconGeneral
Detectors GammaCsI(Tl) scintillator
Sensitivity, gamma radiation Cs-137 Am-241100 s-1/(µSv/h) / (1 s-1/(µR/h)) 100 s-1/(µSv/h) / (1 s-1/(µR/h))
Energy range Gamma0.06 – 3.0 MeV
Indication range Gamma0.01 µSv/h – 99.99 µSv/h / (1 µR/h – 9999 µR/h)
Response time0.25 s
Measurement range Gamma (± 30 % at 137Cs)0.1 µSv/h – 70 µSv/h / (10 µR/h – 7000 µR/h)
Alarm typesvisual, audible and external vibrator
Drop test1, 5 m (5 ft.) onto concrete surface
Power requirementsone AA size battery
Battery lifetimeUp to 1000 hours
CommunicationIR interface
Memory990 data points
Environmental Temperature range LCD indication Humidity-30 to +50 °C (-22 to +122 °F ) -15 to +50 °C (+5 to +122, 5 °F ) up to 95 % at +35 °C (+95 °F )
Ingress Protection RatingIP65
Weight and Dimensions IconWeight and Dimensions
Dimensions110х57х32 mm (41/3 х 21/4 х 11/4 in)
Weight, including battery320 g. (11.29 oz)

Related product manuals