EasyManuals Logo

Polimaster PM1603A User Manual

Polimaster PM1603A
38 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #18 background imageLoading...
Page #18 background image
18
Standard configuration of the dosimeter when shipping ensures indication of the
following parameters and functions performed:
DER indication mode On (enable)
On a display (2), figure 1.2 DER values output
On a display (3) output of the current time seconds On (enable)
On a display (3) output of the coefficient of variation values Off (disable)
On a display (4) output of the current time in hours, minutes On (enable)
On a display (4) output of DER values averaging Off (disable)
Thresholds setting enable: - On (enable)
Audible alarm: - On (enable)
DE indication mode On (enable)
On a display (2), figure 1.2 DE values output
On a display (3) output of DE accumulation time values in thousands hours (symbol
“h” is indicated at DE accumulation time less than a thousand hours)
On a display (4) output of DE accumulation time values in hours On
Thresholds setting enable - On (enable)
DE reset - On (enable)
Audible alarm - On (enable)
Dosimeter’s number indication mode On (enable)
On a display (2), figure 1.2 dosimeter’s number
On a display (3) - month of the dosimeter’s production
On a display (4) - year of the dosimeter’s production
Audible alarm - On (enable)
“Alarm clock” indication mode On (enable)
On a display (2), figure 1.2 the symbol “AL” of the alarm clock mode
On a display (4) hours and minutes
“Timer” indication mode On (enable)
On a display (2), figure 1.2 the symbol “TR” of the timer mode
On a display (3) seconds
On a display (4) hours and minutes
“Stop-watch” indication mode On (enable)
On a display (2), figure 1.2 the symbol “ST” of the stop-watch mode
and decimal parts of a second
On a display (3) seconds
On a display (4) hours and minutes
“Clock-calendar” indication mode On -(enable)
On a display (2), figure 1.2 the day of the week
On a display (3) seconds
On a display (4) hours and minutes
2.4.2 DER indication mode
In the DER mode (figure 2.1) the following parameters are indicated on the LCD:
- DER (µSv/h, mSv/h, Sv/h);
- DER on the analogue scale in a logarithmic gauge (seven segments);
- current time in hours, minutes and seconds or averaging time of DER values
(range of the averaging time indication is from 1 up to 2999 s. If the averaging time

Questions and Answers: