EasyManua.ls Logo

Polygroup SUMMER WAVES ST1600 - User Manual

Polygroup SUMMER WAVES ST1600
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
EN
DISTRIBUTED BY: Polygroup
®
Trading Limited. Unit 606, 6th Floor, Fairmont House, No.8 Cotton Tree Drive, Central, Hong Kong.
For questions and issues, contact Customer Service at +1 (888) 919-0070 from 8AM to 5PM MST, Monday-Friday.
Extended operating days and hours during peak season requirements.
Polygroup
®
Trading Limited (hereinafter “Polygroup
®
”) makes products at the best quality we are able to offer. Polygroup
®
is pleased to
offer warranty for the repair or replacement of pool products for 180 days from the date of purchase. The provisions of this Limited
Warranty only apply to the original purchaser. Please keep your original store sales receipt, as this proof of purchase will be required and
must accompany warranty claims to Polygroup
®
or its designated agents. This Limited Warranty does not apply without proof of purchase;
or should the purchaser modify or repair the product themselves or by unauthorized people; use non-Polygroup
®
parts or accessories with
the product; use the product in contravention of the manufacturers instructions; use improper voltage; abuse the product in any way; or
through accident or negligence. This Limited Warranty will not cover consequential damages, including claims for loss of water, pool
chemicals, damage, or labor, normal wear-and-tear; nor acts of God outside the control of Polygroup
®
. Non-manufacturing defects, such
as grasses that may grow through the ground cloth and/or pool liner are examples of which Polygroup
®
cannot be held responsible for.
IN NO EVENT SHALL Polygroup
®
, ITS AUTHORIZED AGENTS, RELATED ENTITIES, OR EMPLOYEES BE LIABLE TO THE BUYER
OR ANY OTHER PARTY FOR DIRECT OR CONSEQUENTIAL DAMAGES. Some states or countries, or other jurisdictions, do not allow
the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
This Limited Warranty is not extended to close-outs, factory seconds, or resold products (i.e. garage sales, online auctions, or online
retailers not purchased directly from Polygroup
®
). Any issues with items purchased from these types of vendors / sellers will need to be
addressed through these stores. Items purchased from seasonal stores will be treated with an “All Sales Final” Policy.
Limited Warranty
Should you encounter a problem with your Polygroup
®
Product, DO NOT return the product to the place of purchase. All warranty claims must
be made
directly to Polygroup
®
. For any setup and troubleshooting issues, visit support.polygroupstore.com. Customer Service: +1 (888) 919-0070
.
You may be asked to return all or part of the product for inspection and/or repair. Do not return any product to Polygroup
®
without a Return Merchandise
Authorization number.
DO NOT RETURN PRODUCT TO STORE
For answers to common questions, setup videos and
troubleshooting tips, visit support.polygroupstore.com
or call Customer Service: +1 (888) 919-0070
To order parts and
accessories, visit
polygroupstore.com
READ AND KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
EN
SUMMER WAVES
®
SAND FILTER PUMP
FOR ABOVE-GROUND SWIMMING POOLS
ST1100 (10”) / ST1600 (12”) Models
TABLE OF CONTENTS
Warnings
Preliminary Steps, Pump Power Information & Part List
Setup Instructions
Use Of Pump
Pump Motor Care & Pump Maintenance & Pool Water Care
Troubleshooting Guide
Winterizing, Disassembly & Storage
6-Port Valve - Parts List & Setup
ASME Compliant Suction Fitting Info
3 ~ 6
7 ~ 8
9 ~ 13
14 ~16
17
18
19
20 ~ 22
23 ~ 24
EN
©2021
09C3A4USA317

Questions and Answers

Summary

IMPORTANT SAFETY INSTRUCTIONS

Safety Care for Children

Provides guidance on child safety around swimming pools, emphasizing supervision and risk reduction.

Risk of Entrapment

Warns about entrapment hazards from suction outlets and advises on immediate actions if covers are missing.

Risk of Drowning

Advises on preventing child access to pools via fencing and proper placement of pool equipment and toys.

Risk of Electrocution

Emphasizes keeping electrical appliances away from pools and avoiding installation near overhead electrical lines.

Risk of Drowning, Entrapment, and Diving Accidents

PRELIMINARY STEPS

SETUP INSTRUCTIONS

USE OF PUMP

GFCI PLUG INSTRUCTIONS

PUMP MOTOR CARE

TROUBLESHOOTING GUIDE

WINTERIZING, DISASSEMBLY & STORAGE

6-PORT VALVE SETUP

ASME COMPLIANT SUCTION FITTING INFORMATION

Important Information about Suction Outlet Fitting Assembly (SOFA)

Provides critical safety warnings and general information regarding SOFA installation and use.

Installation Requirements and Limitations for Suction Outlet Fitting Assembly (SOFA)

Details the specific requirements and limitations for installing SOFA components to prevent suction entrapment.

Summary

IMPORTANT SAFETY INSTRUCTIONS

Safety Care for Children

Provides guidance on child safety around swimming pools, emphasizing supervision and risk reduction.

Risk of Entrapment

Warns about entrapment hazards from suction outlets and advises on immediate actions if covers are missing.

Risk of Drowning

Advises on preventing child access to pools via fencing and proper placement of pool equipment and toys.

Risk of Electrocution

Emphasizes keeping electrical appliances away from pools and avoiding installation near overhead electrical lines.

Risk of Drowning, Entrapment, and Diving Accidents

PRELIMINARY STEPS

SETUP INSTRUCTIONS

USE OF PUMP

GFCI PLUG INSTRUCTIONS

PUMP MOTOR CARE

TROUBLESHOOTING GUIDE

WINTERIZING, DISASSEMBLY & STORAGE

6-PORT VALVE SETUP

ASME COMPLIANT SUCTION FITTING INFORMATION

Important Information about Suction Outlet Fitting Assembly (SOFA)

Provides critical safety warnings and general information regarding SOFA installation and use.

Installation Requirements and Limitations for Suction Outlet Fitting Assembly (SOFA)

Details the specific requirements and limitations for installing SOFA components to prevent suction entrapment.

Overview

This document serves as an owner's manual for the Summer Waves Sand Filter Pump, designed for above-ground swimming pools, specifically models ST1100 (10") and ST1600 (12"). It provides comprehensive instructions for setup, operation, maintenance, and troubleshooting, emphasizing safety precautions throughout.

The primary function of this device is to filter and circulate water in above-ground swimming pools, ensuring water clarity and hygiene. It utilizes #20 silica sand as a filtration medium, which can be purchased from local home improvement or building material stores. The manual explicitly warns against using incorrect sand, as it may damage the filtration system and void the warranty.

Usage Features:

The sand filter pump is equipped with a 6-Port Valve, which offers multiple functions for pool maintenance:

  • BACKWASH: This setting reverses the water flow to clean the sand bed, preventing fine sand from entering the pool and washing away accumulated dirt and debris. It is recommended to backwash when the pressure reading is 1-1.5 bar (14.5-21.8 psi) above the initial pressure or at least once every two weeks. The Blue Drain Outlet Cap must be removed before using this setting and replaced afterward.
  • RINSE: After backwashing, the RINSE function levels out the sand bed. Similar to backwash, the Blue Drain Outlet Cap must be removed and replaced. Rinsing should be performed for one minute.
  • FILTER: This is the normal operating mode for filtration and vacuuming the pool.
  • WASTE: This setting allows for direct vacuuming to the drain, which helps lower the pool water level. The Blue Drain Outlet Cap must be removed and replaced.
  • RECIRCULATE: This function circulates water without filtering it.
  • CLOSED: This position shuts off the water flow between the sand filter system and the pool. It is crucial not to switch on the pump when the valve is in this position.
  • NULL: This setting is for winterizing and storage, allowing for excess water flow.

The pump is designed for ease of use, with clear instructions for connecting hoses and fittings. It includes a GFCI (Ground-Fault Circuit-Interrupter) power cord set with a pre-set timer function. The default operating time is 10 hours, after which the pump automatically turns off for 14 hours, following a 24-hour cycle. Users can adjust the operating time from 1 to 10 hours using the "SET" button. The manual provides detailed instructions on how to test the GFCI's leakage protection function, emphasizing safety by ensuring the pump stops working if a ground current is detected.

For installation, the manual outlines steps for setting up the pool, installing suction and return fittings, and assembling the pump onto its base. It highlights the importance of aligning the clamp hinge with the ridge on the 6-Port Valve flange for a secure fit. The sand tank should be filled with #20 silica sand, ensuring the sand level is between the Min and Max marks on the Center Pipe.

Maintenance Features:

Regular maintenance is crucial for the longevity and efficient operation of the sand filter pump.

  • Sand Bed Maintenance: Backwash the sand bed regularly, as indicated by pressure readings or at least every two weeks. At the end of the swimming season, all sand should be discarded, and new sand should be used at the beginning of the next season.
  • Cleaning: The pump components, sand tank, and 6-port valve should be thoroughly washed with fresh water before storage.
  • Leak Checks: Daily checks for reduced flow and leaks in the pump, hoses, and fittings are recommended. The troubleshooting guide provides solutions for common leakage issues, including checking gaskets, tightening hose clamps, and inspecting connections.
  • Pump Motor Care: The pump is protected by a thermal switch that automatically shuts it off if it overheats. If this occurs, users should check and correct the water flow, allow the motor to cool for at least 15 minutes, and inspect for blockages in the rotor.
  • Pool Water Care: The manual stresses the importance of maintaining proper chlorine and pH levels at all times, as the filter pump alone cannot prevent algae growth. It recommends daily checks and adjustments of pH and chlorine, with recommended levels between 7.3-7.8 for pH and 1.0-1.6 ppm for chlorine. Superchlorination every other week is also advised. Users are cautioned against high chlorine concentrations and low pH levels, which can damage the pool liner. The manual also suggests using a test kit, floating chlorine dispenser, pH control chemicals, algaecides, and a leaf net for comprehensive pool water care.
  • Winterizing and Storage: For off-season storage, the manual provides steps to unplug the power cord, loosen hose clamps, remove hoses, drain water from the sand tank, and lubricate O-rings. The 6-Port Valve should be turned to the "NULL" position, and the pump should be allowed to dry completely before storing it in a cool, dry environment above 32 degrees Fahrenheit.

Safety Information:

The manual includes extensive safety warnings, such as preventing drowning by supervising children, avoiding diving into shallow water, and staying away from drains and suction fittings to prevent entrapment. It also provides electrical safety guidelines, including connecting to a grounding-type receptacle, using a GFCI, and maintaining a safe distance from electrical outlets. The document references various safety standards and organizations like ASME, ANSI, APSP, and NEC, highlighting the importance of adhering to local and state building codes for pool installation and safety barriers.

Polygroup SUMMER WAVES ST1600 Specifications

General IconGeneral
ModelST1600
Voltage120V
Flow Rate1600 GPH
Recommended Pool SizeAbove Ground Pools
Power0.75 HP
Motor Power0.75 HP

Related product manuals