EasyManua.ls Logo

Polypipe UFHPROGW - Optimum Start and Programming Modes; Daylight Saving and Program Type

Polypipe UFHPROGW
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
22
Floor Temp Limit: When the Floor Sensor has been enabled in feature 05, you can set a
oor limiting temperature between 20-45°C, this protects the oor from overheating.
(27°C is the default).
Optimum Start: Optimum start will delay enabling of the heating system to the latest
possible moment avoiding unnecessary heating and ensure the building has reached its
desired temperature at the programmed time. The thermostat uses the rate of change
information to calculate how long the heating needs to raise the building temperature 1°C.
Rate of Change: Number of minutes to raise the temperature by 1°C.
Note: The user cannot change this feature and is for information only.
Programming Mode: The following program modes are available;
5/2 Day P
rogramming – 4 levels for the weekdays and 4 dierent levels for
the weekend.
• 7 Day Programming – 4 levels for each day.
• 24 Hours – 4 levels over a 24 hour period.
• Non-Programmable Basic up/down override temperature control.
Daylight Saving Time (DST): is where the thermostat sets the clocks forward one hour from
‘Standard Time during the summer months, and back again in autumn, in order to make
better use of natural daylight.
Program Type: You can select between 4 or 6 program/comfort levels.
Model: UFHPROGW

Related product manuals