>2.5m
The heat pump should be located at least 2.5 meter away from the swimming pool.
Pool
3.1 Location
Please comply with the following rules concerning the choice of heat pump location.
1. The unit’s future location must be easily accessible for convenient operation and maintenance.
2. It must be installed on the ground, laid ideally on a level concrete oor. Ensure that the oor is sufciently
stable and can support the weight of the unit.
3. A water drainage device must be provided close to the unit in order to protect the area where it is installed.
4. Check that the unit is properly ventilated, that the air outlet is not facing the windows of neighboring
buildings and that the exhaust air cannot return. In addition, provide sufcient space around the unit for
servicing and maintenance operations.
5. The unit must not be installed in an area exposed to oil, ammable gases, corrosive products, sulfurous
compounds or close to high frequency equipment.
6. To prevent mud splashes, do not install the unit near a road or track.
7. To avoid causing nuisance to neighbors, make sure the unit is installed so that it is positioned towards the
area that is least sensitive to noise.
8. Keep the unit as much as possible out of the reach of children.
3. Installation
The heat pump is very easy to install, only water and power need to be connected during
installation.
Place nothing less than 1,50 m in front of the heat pump.
Leave 30 cm cm of empty space around the sides and rear of the heat pump.
Do not leave any obstacle above or in front of the unit!
≥1500
≥300
≥300
Dimensions in mm