5. Operation
5.1 Operation
Conditions of use
For the heat pump to operate normally, the ambient air temperature must be between 7°C and 43°C.
Recommendations prior to start-up
Before activating the heat pump, please:
Check that the unit is stable.
Check that the gauge indicates a pressure greater than 80 psi.
Control the proper functioning of your electrical installation.
Check that the hydraulic connections are tight and that there is no leakage of water.
Remove any unnecessary object or tool from around the unit.
Operation
1. Connect the unit power plug.
2. Activate the circulating pump.
3. Activate the unit’s power supply protection (differential switch and circuit-breaker).
4. Activate the heat pump by pressing once on .
5. Select the required temperature.
6. The heat pump’s compressor will start up after a few moments.
All you have to do now is wait until the required temperature is reached.
WARNING: Under normal conditions, a suitable heat pump can heat the water in a swimming
pool by 1°C to 2°C per day. It is therefore quite normal to not feel any temperature difference in
the system when the heat pump is working.
A heated pool must be covered to avoid any loss of heat.