INSTALLATION GUIDE
POWER ON & INDICATIONS
Upon applying power, observe the above LED’s.
NORMAL OPERATION: DL3 will come on steady and then begin flashing after a few seconds.
FAULTY OPERATION; DL2 will be flashing RED. This indicates…
§ An error condition exists – correct as necessary
§ Operator requires setup – launch a setup and proceed accordingly
NOTE: DL4 will illuminate yellow anytime a change has been made to the control, such as a speed or time adjustment.
Momentarily press on SW1 to acknowledge the change and extinguish the yellow LED.
HELPFUL NOTES:
§ Speed and time adjustment changes will not take effect until the door closes fully after the adjustment has been made.
§ Hold Open time affects the delay following activation from input 10, 11, and 13.
§ When Dip Switch 5 is ON, the blue speed and time potentiometers are disabled and will have no effect.
DL1 : GREEN USB CONNECTION
DL2: FLASHING RED LED
DL3: BLUE 5V POWER SUPPLY
DL4: BOARD VALUES DIFFER FROM DIP SWITCHES
(PRESS SW1 MOMENTARILY TO EXTINGUISH YELLOW LED)
WWW.PORTALP.COM | 23
Automatic Doors & Building Access Control
SW10 (Full Power) & SW19 (Low Energy)