INSTALLATION GUIDE
WIRING CONNECTIONS (wiring diagrams are located in the Appendix)
– Contact closes upon activation. May be used for fail-secure locks by
routing 1 leg of power through the relay. Relay is triggered by activation inputs 10, 11, or 16.
Relay remains energized until door is fully closed again.
- Contact opens upon activation. May be used for fail-safe locks by routing 1
leg of power through the relay. Relay is triggered by activation inputs 10, 11, or 16. Relay
remains energized until door is fully closed again.
- Closed
N.O. Contact is closed when door is closed. The contact opens as soon as the door opens.
– Common
Common contact for door status.
- Open
– Contact is closed when door is open. The contact opens as soon as the door starts to
close. This input can be used for motor connection at lockout relay when power is looped
through, thus switching power on when door is open.
Requires N.O. Contact between input 10 & COM. Remains capable to activate when dip
switch 3 is ON AND On
-Off switch is OFF.
Requires N.O. Contact between input 11 & COM.
Requires N.C. contact between 12 & COM. Upon open contact, door closes and overrides all
other inputs. Remains jumpered if input is not used.
Requires N.C. contact between 13 & COM. Disabled in full closed position.
Requires N.C. contact between 14 & COM. Upon open contact, (Dip 6 OFF) during opening,
door stops, then resumes at reduced speed when input is released.
N.O. contact, when closed causes door closing. All inputs inhibited during closed contact
(not available on all software versions).
Overhead Presence Sensor
Input
Requires N.O. contact between 14 & +24 VDC (input 9). When input is closed it causes an
open door to stay open and a closed door to stay closed. Works in conjunction with dip
switch #6.
Auxiliary Relay NOTE: Relay is triggered by input 14.
- Common
N.O. output is closed upon closed contact from fire alarm. LED 2 also illuminates.
I/O BOARD CONNECTIONS
TERMINAL STRIP J5TERMINAL STRIP J6
WWW.PORTALP.COM | 28
Automatic Doors & Building Access Control
SW10 (Full Power) & SW19 (Low Energy)