Before Each Start=Up:
Place On/Auto/Off lever to "Off".1.
2.
Pull the regulator knob out and turn counterclockwise to set the outlet
pressure to zero.
3. Attach hose and accessories. NOTE: The hose or accessory will require
a quick connect plug if the air outlet is equipped with a quick connect
socket.
_Risk of Bursting. Too much air pressure causes a
-- hazardous risk of bursting. Check the manufacturer's
maximum pressure rating for air tools and accessories. The regulator
outlet pressure must never exceed the maximum pressure rating.
How to Start:
1. Turn the On/Auto/Off lever to "On/Auto" and allow tank pressure to build.
Motor will stop when tank pressure reaches "cut-out" pressure.
2. Pull the regulator knob out and turn clockwise to increase pressure. When
the desired pressure is reached push knob in to lock in place.
The compressor is ready for use.