PP6000 Command Details - Page 7
6. The status is also transmitted whenever the data sequence of <10>h<05>h<n>(1
n 2) is received.
Example:
In {ESC} * m nL nH dk, d1= <10>h, d2=<05>h, d3=<01>h
6. This command should not be contained within another command that consists of
two or more bytes.
Example:
If you attempt to transmit {ESC} 3 n to the printer, but DTR (DSR for the host
computer) goes to MARK before n is transmitted, and {DLE} {ENQ} 2 interrupts
before n is received, the code <10>h for {DEL} {ENQ} 2 is processed as the code
for {ESC} 3 <10>h.
7. {DLE}{ENQ} 2 enables the printer to recover from an error after clearing the data
in the receive buffer and the print buffer. The printer retains the settings that were
in effect when the error occurred. The printer can be initialized completely by
using this command and {ESC} @. This command is enabled only for errors that
have the possibility of recovery, except for print head temperature error.
CODES
(HEX/CONTROL):
<18> / {CAN}
NAME:
Cancel print data in page mode
FUNCTION:
In page mode, deletes all the print data in the
printing buffer
EXPLANATION:
1. This command executed only in page mode. It is ignored in text mode.
2. All data in page mode print buffer will be cleared. If a repeatable print has been
performed, the printed data will be cleared from print buffer by this command, but
all printing settings including print position remain. In other words, the starting
position for next printing in Page mode follows last position printed.
CODES
(HEX/CONTROL):
<1B> <0C> / {ESC} {FF}