4.1.4 UTC Enhance Command Mode
Command Hex Function Description
ESC u
A..CR
1B 75 41 [data x
20] 0D
Upper line display
ESC u
B..CR
1B 75 42 [data x
20] 0D
Bottom line display
ESC u
D..CR
1B 75 44 [data x
45] 0D
Upper line message scroll continuously
ESC u
E..CR
1B 75 45 hh ‘:’ mm
0D
Set and display 24 hour time
0 h ,m 9≦≦
ESC u F..CR 1B 75 46 [data x
45] 0D
Upper line message scroll once pass
ESC u
H..CR
1B 75 48 n m 0D Change attention code
32 n ,m
( Default attention code n=1Bh, m=75h )
ESC u 1..CR 1B 75 49 [data x
40] 0D
Two line display
ESC RS..CR 1B 0F 0D Change to UTC standard mode
4.1.5 AEDEX Command Mode
Command Hex Function Description
! # 1..CR 21 23 31 [data x
20] 0D
Upper line display
! # 2..CR 21 23 32 [data x
20] 0D
Bottom line display
! # 4..CR 21 23 34 [data x
45] 0D
Upper line message scroll continuously
! # 5..CR 21 23 35 hh ‘:’ mm
0D
Set and display 24 hour time
0 h ,m 9≦≦
! # 5 CR 21 23 35 0D Display 24 hour time
! # 6..CR 21 23 36 [data x
45] 0D
Upper line message scroll once pass
! # 8..CR 21 23 38 n m 0D Change attention code
32 n ,m
( Default attention code n=”!”, m=”#” )
! # 9..CR 21 23 39 [data x
40] 0D
Two line display