EasyManua.ls Logo

Power Flame C2-G-15 - User Manual

Default Icon
55 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
C MANUAL

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Power Flame C2-G-15 and is the answer not in the manual?

Summary

For Your Safety

Warning on Burner Operation

1. General Product Information

Principal of Operation

Explains the basic principles of Power Flame Type C burners.

Standard Burner Dimensional Data

Table 2 Standard Burner Ratings and Component Data

Lists standard burner ratings, capacities, and component data.

3. Mechanical Operation of Fuel;Air Control Modes

Figure 17 Typical Gas Burner with On-Off

Explains the operation of an On-Off gas burner's fuel/air control.

Figure 18 Gas Burner Low-High-Off;Low-High-Low

Details the fuel/air control for Low-High-Off/Low-High-Low gas burners.

Figure 19 Gas Burner with Full Modulation

Explains the fuel/air control for full modulation gas burners.

Figure 20 Oil Burner with On-Off

Details the on-off fuel/air control for oil burners.

Figure 21 Oil Burner Fixed Air Low Fire Start

Explains the fuel/air control for oil burners with fixed air low fire start.

Figure 22 Oil;Gas Burner RALFS

Details the RALFS system for oil or gas/oil burners.

Figure 23 Oil Burner Low-High-Off;Low-High-Low (Webster)

Explains fuel/air control for Low-High-Off/Low-High-Low oil burners using Webster 22R pump.

4. General Start Up Procedures - All Fuels

All Fuels - General Start Up

General procedures for starting up all types of burners.

5. Gas Start Up

Burner Start Up Sequence Instructions

Step-by-step instructions for initiating gas burner start-up.

Table 13 CO₂- O₂ Ratio Curves

Provides curves for correlating CO2/O2 values with excess air and fuel types.

6. Oil Start Up

Burner Start Up Sequence

Step-by-step instructions for initiating oil burner start-up.

8. Maintenance

9. Burner Start Up Information & Test Data

Gas Firing

Section for recording gas firing parameters and test results.

Oil Firing

Section for recording oil firing parameters and test results.

10. Owner Operating Instructions

For Your Safety

Essential safety precautions for operating the burner.

Important Precautions

Key precautions before operating or servicing the burner.

Start Up

General preparation and steps for burner start-up.

Power Flame C2-G-15 Specifications

General IconGeneral
Fuel TypeGas or Oil
Input Range (Gas)400, 000 - 2, 100, 000 BTU/hr
Input Range (Oil)2.8 - 15.0 GPH
Motor1/3 HP
Electrical120/1/60, 208-240/1/60, 208-240/3/60, 480/3/60, 575/3/60
Gas Connection1/2" NPT
Oil Connection1/4" NPT
Ignition TypeElectronic Intermittent Pilot or Direct Spark Ignition
Control TypeModulating
Air AdjustmentAdjustable Combustion Air Band
Flame SupervisionUltraviolet
MaterialSteel
MountingFlange Mount

Related product manuals