3.2 Switch on with “Disabled Green Mode” Function:
When utility input is
connected to the UPS, press “ON” button and keep pressing until the ”Bi……….Bi-Bi”
beeps stopped to turn on the UPS. After that, connect the electrical cords of the
equipments that will be used (such as Notebook computer and LCD monitor) to the rear
panel of UPS. If the load is lighter than 15W, please also refer this function to avoid any
inconvenience cause by “Green Mode” function.
3.3 Switch off:
Press the “OFF” button at “LINE” or “BACKUP” modes and keep
pressing more than 3 second to turn off the UPS.
ATTENTION
:
UPS can automatically charge itself under ”OFF” mode. (Advanced
Battery Management Technology)
3.4 Silence:
When UPS is under “BACKUP” mode, press the “SILENCE” button about
1 second to silence the audible alarm. The function is disabled when UPS is under
condition of “LOW BATTERY” or “OVERLOAD”
3.5 Self-test function:
Press the “TEST” button at “LINE” mode about 0.5 second,
UPS will perform self-test procedure automatically.
ATTENTION:
No load shut-down function can be disabled by pressing button until
bi-bi beep to turn on the UPS.
4. A
LARM
4.1 “BACKUP” (slow alarm):
When the UPS is working under “BACKUP” mode, the
UPS would emit audible alarm. The alarm stops when the UPS is return to “LINE” mode
operation.
ATTENTION:
The alarm of “BACKUP” is going to beep every 2 seconds.
(Slow-speed beep).
ATTENTION:
The UPS provides mute function for the warning. When the beeping
sound occurs, press "ON" to stop it; and press "ON" again to resume the
sound.
4.2 “LOW BATTERY” (rapid alarm):
In the “BACKUP” mode, when the energy of
battery becomes to lower level. (about 20%~30%) The UPS beeps rapidly until the UPS
shuts down from battery exhaustion or returns to “LINE” mode operation.
ATTENTION:
The alarm of the batteries caused by low voltage beeps every 0.5
second.
ATTENTION:
The rapid alarm under “LOW BATTERY” condition cannot be muted.
4.3 “OVER LOAD” (continuous alarm):
When the UPS is working under overload
condition (the connected loads exceed the maximum rated capacity), the UPS will emit
continuous alarm to warn an overload condition. In order to protect the unit and the loads,
the UPS will be automatic turn off. Please disconnect nonessential devices from UPS to
eliminate the overload alarm.