Model
1000
Installation and Operation Manual
Page
7
OFFICIAL 6/1/2001
I
II
I
NSTALLATION
NSTALLATIONNSTALLATION
NSTALLATION
Underwriter’s Laboratories
®
requires this notice for UL
®
listed equipment.
This Notice applies to Brushless DC Drive Model Numbers 1000 and 1000A.
MOTOR PROTECTION CONSIDERATIONS
You are about to install a
GENESIS
Series Brushless DC (BLDC) drive. You need to consider how the motor will be
protected while it is in service. This is what the Model 1000 series drive provides :
1.
“F” Series
motors have an internal switch that opens at high winding temperatures. You must connect this
switch to the drive. Look up the method of connection in the drive manual. When the thermal switch opens, the drive
has to be shut down before high temperatures can cause damage.
2. The Model 1000 series drive provides motor current limiting. This protection is adjustable from 0% to 150% of
the drive’s rated output current.
3. The Model 1000 series drive provides an overcurrent trip. This shuts off the drive if peak currents greater than
300% of the RMS rating occur.
4. The Model 1000 drive provides fast clearing fuses in the AC input. It does not provide an input circuit breaker
unless you chose that option at the time of purchase. If you did not purchase an optional circuit breaker with the drive,
you must supply a switch for input power. You must do this in order to meet the requirements of the National Electrical
Code.
5.
GENESIS
series drives
do not provide running overload protection as described in Underwriters Laboratories
Industrial Control Equipment Specification 508. The user is responsible for complying with local codes and practices. If
you decide you need more protection, that protection must shut off the drive.
SUMMARY
OF WARRANTY AND DISCLAIMER
Powertec
manufactures Model 1000 Series Brushless DC (BLDC) motor controls. We warrant these units against
defects in materials and workmanship for a period of
two years
. This period begins on the date of original shipment
from the factory.
You must notify us in writing of a defect in materials or workmanship in a warranted unit. We
will, at our sole option,
repair or replace such defective parts as we deem necessary to restore the unit to service. We will make these repairs,
or replacement of parts, at the factory. Shipping charges to and from the factory and on-site service charges are the
responsibility of the user.
There is no other warranty. We do not warrant the fitness of purpose for the application intended. This warranty
does not cover accidental or intentional damage or accidental or intentional abuse. This warranty does not cover
results from defective or incorrect installation, interference with other equipment, or any other situation over which
Powertec
has no control.
This warranty does not cover any other claims, including, but not limited to, special, incidental, or consequential
damages.
Powertec
supplies this manual as a guide to the use of
our products. We have used our best efforts to compile this
information. If you find mistakes of fact in this manual, please notify your distributor or
Powertec
at once.
Do not use this device on a circuit capable of delivering more than