24.
25.
www.powertec.net.nz
www.powertec.net.nz
PT2000i DIGITAL INVERTER GENERATOR
Air Filter Maintenance
Air lter maintenance should be performed every 6
months or 100 hours. The air lter may need to be
cleaned more frequently when using in unusually wet or
dusty areas.
1. (A) Remove the screws (1) and then remove
the cover (2).
2. (B) Remove the screws (1) and then remove the air
lter case cover (2).
3. (C) Remove the foam element (1).
4. Wash the foam element in solvent and dry it.
5. Oil the foam element and squeeze out excess oil. The
foam element should be wet but not dripping.
CAUTION!
Do not wring out the foam element when squeez-
ing it. This could cause it to tear.
6. Insert the foam element into the air lter case. Be
sure the foam element sealing surface matches the
air lter so there is no air leak.
CAUTION!
The engine should never run without the foam
element.
7. Install air lter case cover, cover, and screws.
B.
C.
A.
2
1