EasyManuals Logo

PowerTech MP-3735 User Manual

PowerTech MP-3735
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #6 background imageLoading...
Page #6 background image
6
Night mode
If solar array can not provide current or the current is less than 1 Amp
for 5 minutes or more, the controller will switch to Night mode.
Night light function
Press “menu” button 6 times from the default window. Window will
switch to NLF setup interface. Pressenterbutton once, then
using Pageup/Pagedown buttons, choose ONor OFFand then
confirm with theenterbutton.
Timer 1, NLF=ON
With the NLF switched to ON, press “menu” button once from the
NLF window, and the window will switch to Timer1 setup interface.
Press “enter” button once, you can adjust the “Hour”(1-12hours)
via “Pageup/Pagedown” button, and then confirm by “enter”.
Timer 2, NLF=OFF
Pressmenubutton again from Time1, window will switch to
Timer2 setup interface. Press enterbutton once, you can adjust
the Hour(1-12hours) via Pageup/Pagedownbutton, and then
confirm byenter”.
NOTE
Timer1 hour setting controls the time the load is turned ON after entering night mode; Timer2 hour setting
controls the time the load is turned OFF after Timer1 has finished. Once Timer2 is finished, the load will
turn ON automatically untill dawn.(See below diagram)
There are 2 modes of night light load control available: Standard Controller Mode and
Evening/Morning Mode. To program standard controller mode, set NLF=OFF.
The MP-3735 recognizes days and night based on the solar array voltage. NLF will start when the
PV(Voltage) < 10V for a period of time.