6 2261V103-UK
Transducer supply
Front-programmable to 5...13 VDC. It is up to the customer to ensure a max. load of 230 mA (e.g. 6 parallel 350 Ω load cells).
Sense
When the transducer supply is applied, the sense input can be used for compensation for cable resistance to the transducer.
Electrical specifications
Environmental conditions
Operating temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -20 to +60°C
Calibration temperature. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20...28°C
Relative air humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . < 95% RH (non-cond.)
Protection degree . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IP50
Mechanical specifications
Dimensions (HxWxD) (D is excl. pins) . . . . . . . . . . . . . . . . . . . . . . . . 80.5 x 35.5 x 84.5 mm
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130 g
Common specifications
Supply voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19.2...28.8 VDC
Internal consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.2 W
Max. consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.2 W
Sig nal / noise ratio . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Min. 60 dB
Signal dynamics, input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 bit
Signal dynamics, output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 bit
Updating time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 ms
Response time, programmable. . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.06...999 s
Temperature coecient. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . < ±0.01% of span/°C
Linearity error . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . < ±0.1% of span
Eect of supply voltage change. . . . . . . . . . . . . . . . . . . . . . . . . . . < ±0.002% of span/%V
Auxiliary voltages:
Transducer supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5...13 VDC
Load (max.) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230 mA
EMC immuni ty influence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . < ±0.5%
E lectrical spe cifications - INPUT
mV input
Measurement range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -40...100 mV
Min. measurement range (span) . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 mV
Max. oset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70% of selected max. value
Input in relation to supply gnd. . . . . . . . . . . . . . . . . . . . . . . . . . . . > -5 V and < +10 V
Max. cable resistance per wire. . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Ω
Suppression of transducer cable resistance . . . . . . . . . . . . . . . . . . . . > 300
Input resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . > 10 MΩ
Overrange . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0...999% of selected measurement range
Digital input
NPN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pull up 24 VDC / 6.9 mA
PNP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pull down 0 VDC / 6.9 mA
Trig level low . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . < 6 VDC
Trig level high . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . > 10.5 VDC
Pulse width . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . > 30 ms
Electrical specifications - Output
Current output
Signal range. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0...20 mA
Min. signal range (span). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 mA
Max. oset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50% of selected max. value
Load (max.) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 mA / 600 Ω / 12 VDC
Load stability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . < ±0.01% of span/100 Ω
Current limit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . < 23 mA