36 4225V100-UK
Help text overview
Set correct password
Enter advanced setup menu?
Select NAMUR sensor input
Select S0 sensor input
Select PNP sensor input (or Contact to supply)
Select NPN sensor input (or Contact to ground)
Select TTL sensor input
Select Tacho sensor input
Select custom current trigger input
Select custom voltage trigger input
Set low trigger level for input signal
Set high trigger level for input signal
Set input high impedance (high resistance)
Enable internal pull-up on input
Enable internal pull-down on input
Set sensor supply voltage
Set up input for period time measurement
Set up input for rpm measurement
Set up input for frequency measurement
Set input range, low
Set input range, high
Enable input filter (50/60 Hz low-pass / BW-limiter)
Select display unit
Select decimal point position
Set display range, low
Set display range, high
Set display response time [seconds]
Set up output as frequency output
Set up output as current output
Set up output as voltage output
Select active output mode
Select passive output mode
Select 20..-20 mA output range
Select 10..-10 mA output range
Select 20..4 mA output range with safety readback
Select 20..4 mA output range
Select 20..0 mA output range
Select -20..20 mA output range
Select -10..10 mA output range
Select 4..20 mA output range with safety readback
Select 4..20 mA output range
Select 0..20 mA output range
Select 10..-10 V output range
Select 5..-5 V output range
Select 10..2 V output range
Select 10..0 V output range
Select 5..1 V output range
Select 5..0 V output range
Select -10..10 V output range
Select -5..5 V output range
Select 2..10 V output range
Select 0..10 V output range
Select 1..5 V output range
Select 0..5 V output range
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
[9]
[10]
[11]
[12]
[13]
[14]
[15]
[16]
[17]
[18]
[19]
[20]
Select output downscale at NAMUR sensor error
Select output zero output at NAMUR sensor error
Select output upscale at NAMUR sensor error
Select no error action - output undefined - at NAMUR
sensor error
Select Hz as output unit
Select pulses/minute as output unit
Select pulses/hour as output unit
Select pulses/day as output unit
Set output frequency for 0% input
Set output frequency for 100% input
Set output low cut off frequency
Use 50% duty cycle output
Use programmable static pulse time
Set pulse time [milliseconds]
Set output at specific frequency on NAMUR sensor
error?
Set output frequency at NAMUR sensor error
Set up relay in % of input range
Set up relay in display units
Select OFF function - relay is permanently off
Select POWER function - relay indicates power status
OK
Select ERROR function - relay indicates sensor error
only
Select WINDOW function - relay is controlled by 2
setpoints
Select SETPOINT function - relay is controlled by 1
setpoint
Select Normally Closed contact
Select Normally Open contact
Set relay setpoint
Activate relay on decreasing signal
Activate relay on increasing signal
Set relay window setpoint, low
Set relay window setpoint, high
Select relay to be Active Outside Window
Select relay to be Active Inside Window
- NOT USED -
Set relay hysteresis
Select no error action - undefined relay state -
at NAMUR sensor error
Open relay contact at NAMUR sensor error
Close relay contact at NAMUR sensor error
Hold relay status at NAMUR sensor error
Set relay ON delay [seconds]
Set relay OFF delay [seconds]
Enable configurable input limit, low
Enable configurable input limit, high
Set configurable input limit, low
Set configurable input limit, high
Select downscale at limit error
Select zero output at limit error
Select upscale at limit error
Select no error action - output undefined - at limit error
Set output frequency at limit error