9106QF01
LERBAKKEN 10, 8410 RØNDE DENMARK
Revision date:
2019-04-04
Version Revision
V5 R0
Prepared by:
PB
Page:
2/5
9106B1A, 9106B1B
Ex input : Loop current source
CH1 (terminal 43,44)
CH2 (terminal 53,54)
U
o
: 27.5 V
I
o
: 92.6 mA
P
o
: 0.64 W
IIC or A,B IIB or C,E,F IIA or D,G
C
o.
0.084
F 0.670F 2.24
F
L
o.
4.14 mH 16.58 mH 33.17 mH
L
o
R
o
-------- 223 µH/Ω 447 µH/Ω
-20 ≤Ta ≤ +60ºC
(terminal 11,12,13,14)
(terminal 31,32,33,34)
(terminal 91,92,93,94,95)
U
m
: 253V, max 400Hz
44
43
42
41
54
53
52
51
34
33
32
31
14
13
12
11
9106
4501
91 92 93 94 95
Power
Rail
CH1
CH2
T
T
_
+
+
_
9106B2A, 9106B2B
Ex input : Loop current source
CH1 (terminal 43,44)
CH2 (terminal 53,54)
U
o
: 25.3 V
I
o
: 96 mA
P
o
: 0.61 W
IIC or A,B IIB or C,E,F IIA or D,G
C
o.
0.104
F 0.818F 2.85
F
L
o.
3.85 mH 15.43 mH 30.86 mH
L
o
/ R
o
--------- 234 µH/Ω 468 µH/Ω
Simple Apparatus or
Intrinsic safe apparatus
with entity parameters:
Vmax (Ui) ≥ Vt (Uo)
Imax (Ii) ≥ It (Io)
Pi ≥ Pt (Po)
Ca ≥ C
cable + Ci
La ≥ L
cable + Li
Hazardous Classified Location Unclassified Location or
Class I/II/III, Division 1, Group A,B,C,D,E,F,G Hazardous Classified Location
or Class I, Zone 0/1 Group IIC, [AEx ia] IIC Class I, Division 2, Group A,B,C,D T4
or Group IIC, [Ex ia Ga] IIC Gc or Class I Zone 2 Group IIC T4 Gc
32 9106 - Product version 9106-002