EasyManuals Logo

PR electronics 9106 User Manual

Default Icon
50 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #32 background imageLoading...
Page #32 background image
9106QF01
LERBAKKEN 10, 8410 RØNDE DENMARK
Revision date:
2019-04-04
Version Revision
V5 R0
Prepared by:
PB
Page:
2/5
9106B1A, 9106B1B
Ex input : Loop current source
CH1 (terminal 43,44)
CH2 (terminal 53,54)
U
o
: 27.5 V
I
o
: 92.6 mA
P
o
: 0.64 W
IIC or A,B IIB or C,E,F IIA or D,G
C
o.
0.084
F 0.670F 2.24
F
L
o.
4.14 mH 16.58 mH 33.17 mH
L
o
/
R
o
-------- 223 µH/Ω 447 µH/Ω
-20 ≤Ta ≤ +60ºC
(terminal 11,12,13,14)
(terminal 31,32,33,34)
(terminal 91,92,93,94,95)
U
m
: 253V, max 400Hz
44
43
42
41
54
53
52
51
34
33
32
31
14
13
12
11
9106
4501
91 92 93 94 95
Power
Rail
CH1
CH2
T
T
_
+
+
_
9106B2A, 9106B2B
Ex input : Loop current source
CH1 (terminal 43,44)
CH2 (terminal 53,54)
U
o
: 25.3 V
I
o
: 96 mA
P
o
: 0.61 W
IIC or A,B IIB or C,E,F IIA or D,G
C
o.
0.104
F 0.818F 2.85
F
L
o.
3.85 mH 15.43 mH 30.86 mH
L
o
/ R
o
--------- 234 µH/Ω 468 µH/Ω
Simple Apparatus or
Intrinsic safe apparatus
with entity parameters:
Vmax (Ui) ≥ Vt (Uo)
Imax (Ii) ≥ It (Io)
Pi ≥ Pt (Po)
Ca ≥ C
cable + Ci
La ≥ L
cable + Li
Hazardous Classified Location Unclassified Location or
Class I/II/III, Division 1, Group A,B,C,D,E,F,G Hazardous Classified Location
or Class I, Zone 0/1 Group IIC, [AEx ia] IIC Class I, Division 2, Group A,B,C,D T4
or Group IIC, [Ex ia Ga] IIC Gc or Class I Zone 2 Group IIC T4 Gc
32 9106 - Product version 9106-002

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the PR electronics 9106 and is the answer not in the manual?

PR electronics 9106 Specifications

General IconGeneral
BrandPR electronics
Model9106
CategoryRepeater
LanguageEnglish