EasyManua.ls Logo

PRACTIXX PX-RRM-2000WI - Technical Specifications; Lawnmower and Connectivity Specs; Power Supply and Protection Ratings

PRACTIXX PX-RRM-2000WI
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
w ww.practixx .com
GB
|
29
Avoid accidental starting of the machine: the oper-
ating button may not be pressed when inserting the
plug in an outlet. Use the tool that is recommended
in this operating manual. This is how to ensure that
your machine provides optimum performance.
Keep your hands away from the working area when
the machine is in operation.
6. Technical data
Robotic lawnmower
Voltage 20 V
Idle speed n
0
2300 rpm
Cutting width 22 cm
Cut height 20-60 mm
Area 2000
Max. incline 35%
Tightest possible passage 0.8 m
LED light Yes
Ultrasound sensor Yes
(App) control
Bluetooth
®
Operating frequency band 2.4-2.48 GHz
Maximum transmitted power 20 dBm
WiFi
Frequency range of the WLAN
module
2.4-2.48 GHz
Max. radio frequency power
of the WLAN module
20 dBm
Battery LBF205 Lithium-ion / 5.0Ah
Type Li-ion
Voltage 18 V (max. 20 V )
Capacity 5.0Ah
Power 90 Wh
Charge time ca. 96 min
CGF253 power supply
Voltage (input) 100-220 V~
Frequency 50-60 Hz
Power consumption 76 W
Voltage (output) 20 V
Charge current 3.0 A
IP protection classes
Robotic lawnmower IPX5
Charging station IPX4
Power supply IP67
Total weight (net) approx. 11.0 kg
Only charge the product with the battery charg-
er specied by the mower. Do not use a battery
charger other than the one specically intended for
use with the product. A battery charger suitable for
one type of battery may cause a re hazard when
used with another battery.
Do not use batteries that are not intended for use
with the product.
Keep the battery out of the reach of children.
Keep the original product description safety for fu-
ture reference.
Dispose of the product properly.
Keep the battery charger clean. Dirt results in a
risk of electric shock.
Check the battery charger, cable and plug before
every use. Do not use the battery charger if you
detect any damage. Never open the battery charg-
er yourself and only have it repaired by qualied
specialists and only with original spare parts. A
damaged battery charger, cable and plug increases
the risk of an electric shock.
Always check that the mains voltage concurs with
the voltage specied on the type plate of the bat-
tery charger.
Never use the battery charger if the cable, plug
or the product itself are damaged due to external
inuences. Take the battery charger to the nearest
specialist workshop.
Never open the battery charger. Take the battery
charger to the nearest specialist workshop.
m ATTENTION!
This power tool generates an electromagnetic eld
during operation. This eld can impair active or pas-
sive medical implants under certain circumstances.
In order to prevent the risk of serious or deadly injuries,
we recommend that persons with medical implants
consult with their physician and the manufacturer of
the medical implant prior to operating the machine.
Residual risks
The machine has been built according to the state-of-
the-art and the recognised technical safety require-
ments. However, individual residual risks can arise
during operation.
Health hazard due to electrical power, with the use
of improper electrical connection cables.
Before performing setting or maintenance work, re-
lease the start button and pull out the power plug.
Furthermore, despite all precautions having been
met, some non-obvious residual risks may still re-
main.
Residual risks can be minimised if the “Safety In-
structions” and the “Intended Use” together with the
operating manual as a whole are observed.

Related product manuals