C776i Stairclimber
Page 16
Section Four - Checking Unit Operation
This section provides you with a method of checking climber operation. Check climber operation
at the end of a maintenance procedure and when it is necessary to ensure that the climber is
operating properly.
Procedure
1. Start “stepping” on the climber. When the Precor banner prompt appears, press QUICK
START.
2. Operate the climber 4–5 minutes. As you operate the climber:
a. Concentrate on the resistance of the climber and the sound of the stair arm belts and
return springs as you pedal. Be on the alert for unusual rubbing, hitting, grinding, or
squeaking noises
b. Press the Change keys. Verify that various information displays are functioning.
c. Make sure that the stair arm belts do not rub on the cover.
5. If you feel no resistance as you step, if the climber makes unusual noises, or the electronic
display does not change appropriately...
THEN... OTHERWISE...
Refer to Section XX Continue with the next step.
6. Press the STEP RATE
▲ key until you reach Step Rate 60 (60 steps per minute). Operate
the climber for another 2–3 minutes.
7. If the climber resistance does not change or the climber operation feels inconsistent
compared with Work Level 1...
THEN... OTHERWISE...
Refer to Section XX Continue with the next step.
8. Press the STEP RATE
▲ key until you reach Step Rate 90. Operate the climber for another
2–3 minutes.
9. If the climber resistance does not change or the climber operation feels inconsistent
compared with Step Rates 30 and 60...