Procedure 6.7 - Replacing the Line Filter
1. Set the treadmill circuit breaker in the “off” position and unplug the treadmill’s line cord from
the AC outlet.
2. Remove the sheet metal screw that is approximately in the center of the treadmill dress
panel. Remove the four bolts that fasten the treadmill dress panel to the treadmill.
3. Disconnect all of the wiring from the line filter.
4. Remove the mounting hardware that fastens the line filter to the treadmill dress panel.
5. Set the replacement line filter in it’s mounting position, the side with three terminals must
face the circuit breaker. Fasten the line filter to the treadmill dress panel with the mounting
hardware removed in step 4.
6. Connect the wiring to the line filter per Diagram 6.10.
7. Replace the AC line filter wiring as shown in Diagram 6.5.
8. Set the dress panel in its mounting position, hand start the four mounting bolts and the sheet
metal screw removed in step 2. Torque the four dress panel bolts to 120 inch pounds.
Torque the sheet metal screw to 90 inch pounds.
9. Replace the hood per Procedure 6.11.
10. Check treadmill operation per Section 3.