EasyManuals Logo

Precor C960 User Manual

Precor C960
89 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #54 background imageLoading...
Page #54 background image
C960 Series Commercial Treadmill
Page 54
Procedure 6.3 - Replacing the Lift Motor Capacitor
WARNING
Always turn off the circuit breaker and unplug the treadmill before you remove the treadmill hood.
Removing the Lift Motor Capacitor
1. Remove the hood
2. Remove the black and red wires from the lift motor capacitor terminals.
3. Loosen the screw and nut on the capacitor mounting bracket.
Note:
If you are servicing a 240-volt 960 series treadmill, use a phillips screwdriver to loosen and
tighten the screw on the capacitor mounting bracket.
4. Remove the capacitor from the mounting bracket.
Replacing the Lift Motor Capacitor
5. Position the lift motor capacitor in the capacitor mounting bracket.
Note:
Wire length and wire assembly configuration may limit the mounting orientations of the lift motor
capacitor. Make sure that the wires you removed from the capacitor will reach the capacitor
terminals before you perform the next step.
6. Tighten the screw and nut on the capacitor mounting bracket.
7. Connect the wires removed in Step 2 to the capacitor terminals.
Note:
Because the lift motor capacitor is not polarized, you can connect wires to either terminal.
However, you cannot mix wire colors on any one terminal.
8. Check the operation of the treadmill as described in Section Three of this appendix.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Precor C960 and is the answer not in the manual?