EasyManua.ls Logo

Precor EFX 5.33 - Procedure 7.23 - Replacing a Stairarm Connector; Stairarm Connector Replacement

Precor EFX 5.33
94 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5.33 Elliptical Fitness Crosstrainer
Page 75
Procedure 7.23 - Replacing a Stairarm Connector (serial
codes CR and ST, only)
Warning: Care must be taken when work is being performed in the area of the stairarms. Pinch
points exist between the stairarm and ramp and between the stairarm and crankarm,
when the rear covers are removed.
1. Procedure
1. Set the on/off switch in the off position.
2. Remove the retaining clip that fastens the secondary link to the stairarm connector.
3. Remove three bolts, washers and single nut that fasten the stairarm connector to the
stairarm.
Diagram 7.25 - Stairarm Connector Mounting
4. Set the replacement stairarm connector at its mounting position and slide the secondary link
onto the stairarm connector. Replace, but do not tighten the hardware removed in step 3.
Secondary Link
Stairarm Connector

Table of Contents