General Safety and Maintenance Manual: Daily Inspection 12
Some obvious signs of cable damage are as follows:
1. Exposed inner wire, stretching or cuts in the coating, or broken
coating in the area that passes over a pulley
2. A zigzag or wavy pattern
3. Kinks, which may indicate internal damage
4. A necked-down cover
5. A ‘ballooned” cover
Figure 1: Signs of cable damage
In addition to inspecting the cables and end connections for damage,
check the following:
Ensure that each cable is properly adjusted and tightened at the top
of the weight stack.
Check cable pulleys, end connections, and end fittings. Make sure
all connections are tight, adjusting cable tension as necessary.
Make sure that the cable bolt is threaded at lease seven turns into
the selector stem or a minimum of ¹₂-inch (13 mm). The distance
shown should be ³₄-inch (19 mm) or less. Tighten the locking jam
nut to 600 in-lb (68 N-m). Refer to Figure 2.
Figure 2: Proper cable bolt insertion
Exposed inner wire
Zig-zag/wavy
Kinked
Necked-down
Ballooned
Cable bolt must be inserted a
minimum of 7 threads into the
selector stem.
Locking jam nut